4. TROUBLESHOOTING GUIDE
Problem
Dehumidifier does not start.
| Possible Causes | Remedy | |||
|
|
|
|
|
|
| The dehumidifier is unplugged. |
|
|
| Make sure the dehumidifier's plug is |
|
|
|
|
| pushed completely into the outlet. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dehumidifier does not dry the air as it should.
The fuse is blown/circuit breaker is tripped.
Water has reached its preset level.
Bucket is not in the proper position and light is on.
Check if wiring loose or fails.
The control may not be set high enough.
Room temperature is too low.
Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
Empty the bucket and replace properly.
Make sure the slots on both sides of the bucket are positioned correctly.
Replace wiring.
Turn the Humidity Control knob to a higher number.
Moisture removal is best at higher room temperatures.
Lower room temperatures will reduce the moisture removal rate.
This unit is designed to be operated at temperatures above 65° F(18° C)
Ineffective dehumidifying
Airflow is restricted.
Doors and windows may not be closed tightly.
Clothes dryer may be blowing
Check for gas leakage at heat exchange and connecting tube.
Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier.
Check that all doors, windows and other openings are securely closed.
Install the dehumidifier away from the dryer.
The dryer should be vented to the outside.
Repair gas leak.
Noise
Check if the air filter are clogged Clean the air filter. with dust.
| Check if the unit is securely |
|
|
| Set and use the dehumidifier at a |
|
|
|
|
|
| ||
| positioned. |
|
|
| sturdy, flat, and level place. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|