3.2.7 FAN AND MOTOR
1.Turn the nut left and full out the Fan by hands carefully.
2.Remove 2 screws that fasten Heat Exchange.
3.Lift the H/E and open the H/E around 45 degree clockwise carefully. (See Figure 14)
4.Unfasten 3 screws that secure the Motor and earth wire. (See Figure 15)
5. Remove the Motor.
Figure 14 | Figure 15 |
3.2.8 SHROUD AND BARRIER
1.Discharge the refrigerant by using a refrigerant Recovery System.
2.After purging the unit completely, unbrace the Discharge and the Suction tube connected compressor carefully.
3.Remove 2 screws that fasten the H/E.
4.Unfasten 3 screws that secure the shroud on back and sides and upward the shroud from Barrier.
5.Unfasten 2 screws that secure the Barrier to base pan.
6.Pull the Barrier backward then take it up from the base.
Figure 16
— 12—