3.2.7 FAN AND MOTOR

3.2.7 FAN AND MOTOR

1.Turn the nut left and full out the Fan by hands carefully.

2.Remove 2 screws that fasten Heat Exchange.

3.Lift the H/E and open the H/E around 45 degree clockwise carefully. (See Figure 14)

4.Unfasten 3 screws that secure the Motor and earth wire. (See Figure 15)

5. Remove the Motor.

Figure 14

Figure 15

3.2.8 SHROUD AND BARRIER

1.Discharge the refrigerant by using a refrigerant Recovery System.

2.After purging the unit completely, unbrace the Discharge and the Suction tube connected compressor carefully.

3.Remove 2 screws that fasten the H/E.

4.Unfasten 3 screws that secure the shroud on back and sides and upward the shroud from Barrier.

5.Unfasten 2 screws that secure the Barrier to base pan.

6.Pull the Barrier backward then take it up from the base.