Goldstar DHA3012DL, DHA4012DL, DHA5012DL, DH5010B, DH3010B Refrigerating Cycle, Figure Figure Figure

Models: DH5010B DHA5012DL DHA4012DL DH3010B DHA3012DL

1 27
Download 27 pages 51.98 Kb
Page 13
Image 13
3.3 REFRIGERATING CYCLE

3.3 REFRIGERATING CYCLE

3.3.1CONDENSER, EVAPORATOR AND CAPILLARY TUBE(HEAT EXCHANGE ASSEMBLY)

1.Remove the insulation on the H/E assembly

2.Pierce the pinch-off tube to discharge the refrigerant, using a FREONTM recovery system.

3.After discharging the refrigerant completely, remove 2 screws between the shroud and H/E. (See Figure 17)

4.Lift the H/E and open the H/E around 45 degree clockwise carefully.

5.Unbrace two interconnecting tubes of the evaporator and condenser carefully.

6.Remove the H/E assembly from the shroud. (See Figure 18)

7.Unbrace the capillary tube at the connections of each condenser and evaporator. (See Figure 19)

8.Remove 4 screws between condenser and evaporator. (See Figure 19)

— 13—

Figure 17

Figure 18

Figure 19

Page 13
Image 13
Goldstar DHA3012DL, DHA4012DL, DHA5012DL, DH5010B, DH3010B service manual Refrigerating Cycle, Figure Figure Figure