3.2 CONTROL PARTS

3.2 CONTROL PARTS

3.2.1ROTARY SWITCH, HUMIDISAT AND NEON LAMP

1.Unfasten screws located in the bottom side of control box

(see Figure 9) and fasten capacitor clamp. (DH5010B/DH4010B) And then unfold two sides of control box. (See Figure 9)

2.Disconnect housing and all leads of rotary switch, humidistat and neon lamp.

3.Remove 4 screws which fasten the rotary switch and humidistat.

4.Pull the neon lamp out.

3.2.2 CAPACITOR

1.Remove each screw that fastens capacitor after control box is stretched upper wand.(See Fig. 9)

2.Disconnect all leads of capacitor then remove them from control box.

3.2.3 DEFROST CONTROL (Some Models)

1.Disconnect all leads of the defrost control in the Control Box.

2.Remove the defrost control from the suction tube. (See Figure 10)

3.2.4 THERMOSTAT CONTROL(Some Models)

1.Disconnect all leads of the thermostat on the control box.

2.Remove the capacitor in the control box.(some models)

3.Remove two screws that fasten the thermostat from the control box. (See figure 11)

3.2.5 MICRO SWITCH ASSY

1.Disconnect the housing with three leads connected in the Micro switch.

2.Turn the nut left and take off the micro switch from the barrier. (See Figure 12)

3.2.6 POWER CORD ASSY

1.After the control box opens, remove a screw that fastens the earth wire of the Power cord.

2.Disconnect housing and all leads of power cord then remove it from the unit. (See Figure 13)

— 11—