CONDITION | CAUSE | REMEDY |
|
|
|
5. Noisy operating | Fan | If cracked, out of balance, or partially |
|
| missing, replace it |
|
|
|
| Some material plunged and rattle. | Remove it. |
|
|
|
| Tube hits frame. | Adjust tubing routine carefully. |
|
|
|
| Fan blade hits frame | Check Motor Mount. If loose, tighten it. |
|
|
|
| Internal compressor noise. | Replace compressor. |
|
|
|
| Loose set screws | Tighten them. |
|
|
|
| Worn bearings of Motor Assembly | If knocking sounds continue when running |
|
| or loose, replace the motor. If the motor |
|
| hums or noise appears to be internal while |
|
| running, replace motor assembly. |
|
|
|
6. Water drips | The bucket is not installed properly. | The bucket should be properly positioned |
|
| on the hangers of the drain pan. |
|
|
|
| Connection may be loose. | Check connection and repair. |
|
|
|
| Leak in bucket | Replace bucket. |
|
|
|
| Water drips when bucket removed for | Before removing bucket, the unit should |
| emptying. | be turned off. |
|
|
|
| Bucket overflows. | Check micro switch and float. |
|
|
|
7. Compressor cycles on overload | High or low line voltage. (115V ± 10%) | Check line voltage. It must be between |
protector. (O.L.P.) |
| 103.5V and 126.5V volts. |
|
| If intermittent, provide new supply. |
|
|
|
| Poor air circulation. | Move dehumidifier for free and |
|
| unobstructed air flow. |
|
|
|
| Heat Exchange clogged with dust or dirt. | Clean dust or dirt on the Heat Exchange. |
|
|
|
| Motor | If not running, determine the cause. |
|
| Replace if required. |
|
|
|
| Bad P.T.C. assembly (if assembled) | Check P.T.C., Repair. |
|
|
|
| Short circuit or ground in electrical circuit | Check electrical circuit. Repair. |
|
|
|
| Unit pressures not equalized | Allow 2 or 3 minutes for pressure to |
|
| equalize before starting compressor. |
|
|
|
| Capacitor | Test the capacitor. |
|
|
|
| Wiring | Check the terminals. If loose, repair or |
|
| replace. |
|
|
|
| Refrigeration system | Check the system for a restriction. |
|
|
|
| Stuck compressor | Check compressor, replace compressor |
|
|
|
| Overload protector (O.L.P.) | Check O.L.P., if externally mounted. |
|
| Replace if open. (If the compressor |
|
| temperature is high, remove the O.L.P., |
|
| cool, and retest.) |
|
|
|