A.O. Smith 315795-000 MH Repair Parts List, Metal Drain PAN Thermostat Shield Manifold Assembly

Page 27

REPAIR PARTS LIST

Key No.

Part Description

1

Air Duct Assembly (12” to 24” Long)

2

Angle Bracket (2 Required)

3

Angle Bracket

4

Anode Rod

5

Burner

6

Manifold Assembly

7

Metal Drain Pan

8

Drain Valve

#9

Drain Valve Washer (17/32”x13/64”x1/8” thick)*

10

10” Extension Pipe (Optional)

11

Flue Baffle

12

Gas Control Valve/Thermostat

13

Gasket - Air Intake

14

Piezo Igniter Assembly

15

Nipple w/Heat Traps

16

Outer Door

#17

Optional 3” Outside Wall

Intake Air Vent Kit 9002986005

 

#17

Optional 4” Outside Wall

Intake Air Vent Kit 9002987005

 

18

Pilot Burner (Natural Gas)

18

Pilot Burner (L.P. Gas)

19

Pilot Tubing w/Fittings

20

Pipe Insulation

21

Roof Jack 12” (9002964005)

21

Roof Jack 32” (9002965005)

21

Roof Jack 60” (9002966005)

21

Roof Jack 95” (9002967005)

22

Securing Clamp Assembly

23

T&P Insulation

24

Temperature-Pressure Relief Valve

25

Thermocouple

26

Thermostat Shield

27

Vent Cap

*These parts available at most hardware stores.

# Not Shown.

Now that you have purchased this water heater, should a need ever exist for repair parts or service, simply contact the company it was purchased from or direct from the manufacturer listed on the rating plate on the water heater.

Be sure to provide all pertinent facts when you call or visit.

Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed accordingly.

The model number of your Gas Water Heater will be found on the rating place located above the gas control valve/thermostat.

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:

MODEL NUMBER

TYPE GAS (NATURAL OR PROPANE (L.P.)

SERIAL NUMBER

PART DESCRIPTION

THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.

METAL DRAIN PAN

THERMOSTAT SHIELD

 

7

 

 

26

MANIFOLD ASSEMBLY

6

27

Image 27
Contents For USE only in Manufactured Homes Residential Direct Vent GAS Water HeatersImportant Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsThermostat Shield Optional Typical InstallationHotter Water can Scald Facts to Consider about the Location Locating the NEW Water HeaterInsulation Blankets Water Heater Installation Installing the NEW Water HeaterBasement or crawl space Securing Water Heater to Floor and WallRoof Jack Installation ALL Models ALL 50 Gallon 189.27 Liter ModelsHRS Movement Complete Joint SETValve and Pipe Insulation Water PipingTEMPERATURE-PRESSURE Relief Valve GAS Piping Filling the Water HeaterFor 50 Gallon Heater Sediment TrapsFor 30 Gallon Heater For 40 Gallon HeaterPage For 30 Gallon Heater Page Condensate Temperature RegulationFor Your Information Start UP ConditionsOperational Conditions Burner Inspection Periodic MaintenanceBurner Cleaning Venting System Inspection Immediately correct any if found Anode ROD Inspection Draining Water system. Check for any leaksDrain Valve Washer Replacement ServiceLeakage Checkpoints Troubleshooting Guidelines Metal Drain PAN Thermostat Shield Manifold Assembly Repair Parts ListPage Page UNE NON ET Rechange DE Pièces DE Liste UNE EST Ceci Rechange DE Pièces DES ListeSuie DE Formation Dépannage DE DirectivesTrop PAS LA DE Rondelle LA DE RemplacementFuites DE Vérification DE Points Vidange DE Soupape’ANODE Tige LA DE Inspection Brûleur DU Nettoyage .37 Figure Périodique EntretienEntretien Brûleur DU InspectionFonctionnement DE Conditions Condensation Information Votre PourTempérature LA DE Régulation Démarrage DE ConditionsMort la ou corporelles blessures des matériels ’APPAREIL Vers GAZ LE CouperEAU-CHAUFFE Gallons 30 Pour Naturel GAZ AU .L.P Propane GAZ DUGallons 50 DE EAU-CHAUFFE UN Pour Gallons 40 DE EAU-CHAUFFE UN PourVoir basse, plus la position sa à Droite la vers tourné 19 à 9 étapes lesCe jusqu’à 30 FigureModèle DU Signalétique Plaque LA SUR Listé Celui QUE Sédiments À TrappesGallons 30 DE EAU-CHAUFFE UN Pour Et eau,-chauffe le dessert qui gaz en d’alimentation Remplacement le requiert Ceci .supplémentaire pieds 000 1 mGAZ DE Conduite EAU-CHAUFFE LE RemplirPression DE ET Température DE Décharge DE Soupape Potable non d’eau système un à pas connectez Ne Prudence’EAU Canalisation DE Réseau Tuyaux DES Isolation ET P & T DE SoupapeComplet Joint DU Tableau JEU Mouvement DE Joints DES Pour Approximatif Prise DE TempsRaccords LES ET Cpvc OU ABS PVC, Tuyau LE Cimenter Gallons 50 Litres 189,27 Modèles LES Tous Modèles LES TousPente en toit un sur utilisation Cheminée DE Trémie LA DE InstallationMUR AU ET Plancher AU EAU-CHAUFFE LE Fixer EAU-CHAUFFE DU Installation EAU-CHAUFFE Nouveau LE InstallerBlankets Insulation De l’air blessures, des éviter PourDétectée est fuite la lorsque Respectés être doivent EAU-CHAUFFE Nouveau DU L’EMPLACEMENT Choisir’EMPLACEMENT DE Sujet AU Considérer À Faits » eau-chauffe nouveau le Installer « section la dansÉbouillanter Peut Chaude Plus L’EAU DE Typique InstallationGAZ AU Modèles EAU-CHAUFFE Votre Connaissez Matières DES Table ’INSTALLATION Pour Préparer SEGénérale Sécurité Importantes Définitions Entretien ET Utilisation .SÉCURITAIRE Installation000-15795 Pièce DE .NO Unis-États AUX Imprimé EAU-CHAUFFE LE SUREAU-CHAUFFE CE PAR Utilisé GAZ AU Ajouté EST Odorisant UN