A.O. Smith 650A, 740A, BTP(V)-540A warranty ROUGH-IN Dimensions, Foreword

Page 2

ROUGH-IN DIMENSIONS

STANDARD BAROMETRIC DRAFT CONTROL

HORIZONTAL & DIRECT VENTING

BTP MODELS

BTPV MODELS

MAXIMUM TOTAL 75 EQUIVALENT

FEET INTAKE AND EXHAUST

ALLOWED.

ALL DIMENSIONS IN INCHES (MILLIMETERS)

 

 

 

 

 

 

 

 

 

 

Gas

Approx.

Models

A

B

C

D

E

F

G

H

I

Conn.

Ship. Wt.

BTP(V)-540A

80 3/4

73

32 1/4

9

6

26 1/2

93

29 1/2

48 1/2

1*

950

2,051

1,854

819

229

152

673

2,362

749

1,232

25.4

431 kg

 

BTP(V)-650A

80 3/4

73

32 1/4

9

8

26 1/2

93

29 1/2

48 1/2

1*

950

2,051

1,854

819

229

203

673

2,362

749

1,232

25.4

431 kg

 

BTP(V)-740A

80 3/4

73

32 1/4

9

8

26 1/2

93

29 1/2

48 1/2

1*

950

2,051

1,854

819

229

203

673

2,362

749

1,232

25.4

431 kg

 

*Minimum gas supply pipe is 1 1/4”, reference Table 7 for gas supply pipe size.

 

Storage

Input Rating

Recovery Rating

Recovery Rating

Current Draw

 

Capacity

BTU/HR.

GPH

GPH

120V

Models

U.S. Gals. (Litres)

Nat.

100°F Rise

140°F Rise

60Hz 1 Phase

BTP(V)-540A

85

(261)

540,000

523.6

374

 

BTP(V)-650A

85

(261)

650,000

630

450

6.0 Amps

BTP(V)-740A

85

(261)

740,000

718

512

 

 

 

 

 

 

 

 

Based on 80% thermal efficiency obtained in A. O. Smith engineering laboratories.

NOTE: To compensate for the effects of high altitude areas above 2000 feet, recovery ratings should be reduced approximately 4% for every 1000 feet above sea level.

FOREWORD

The design of the BTP 540A through 740A models complies with ANSI Z21.10.3/CSA 4.3 as an automatic circulating tank and an automatic instantaneous type heater. The BTPV 540A through 740A models are designed for sidewall venting and direct venting applications and are certified under UL 795.

Detailed installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and methods of piping necessary. It is highly essential that all water, gas piping and wiring be installed as shown on the diagrams.

Particular attention should be given to the installation of thermometers at the locations indicated on the diagrams, as these are necessary for checking the proper functioning of the heater.

THE HEATER IS DESIGNED TO OPERATE ONLY ON NATURAL GAS.

THESE HEATERS MUST NOT BE INSTALLED ON COMBUSTIBLE FLOORS.

2

Image 2
Contents Installation Operation Maintenance Limited Warranty Models BTPV-540A, 650A and 740AROUGH-IN Dimensions ForewordTable of Contents General Safety InformationFeatures Extended NON-USE PeriodsRequired Ability Installation InstructionsDishwashing Machine Requirement UncratingAIR Requirements Hard WaterClearances VentingHorizontal SIDE-WALL Venting For Btpv Models Barometric Draft Control AssemblyVertical Venting for BTP Models Vent ConnectionsVent System Installation Vent Terminal LOCATIONS-EXHAUSTDirect Venting for Btpv Models Vent Terminal LOCATIONS-INTAKEDirect Vent System Installation Drain Valve and Access Panels GAS PipingGAS Pressure Regulation ANY Supply Pressure Testing Exceeding 1/2 PSIG. GASGAS Meter Size City Gases only GAS ValvesSystem Connections Water Line ConnectionsRelief Valve Installation Diagrams Circulating Pump Wiring DiagramWiring Diagram for Tempered Water Loop if Used Circulating Pump Wiring Diagram Page Manifold Kits Purging Heater WiringStart UP FillingPage Page For Your Safety Read Before Lighting Sequence of Operation Adjustment for High Elevation Application Premix LOW NOx Burner Exploded View for BTP Models Premix LOW NOx Burner Exploded View for Btpv Models Maintenance General InformationLime Scale Removal DrainingSediment Removal Checklist and Service Water Heater Makes Sounds TroubleshootingWater is TOO HOT HOT Water OdorMotor will not RUN Burner Lockout Once in a WhileNoisy Burner Operation GAS Fails to Shut OFFModel Btpv Limited Warranty Page Page Replacement Parts