A.O. Smith BTP(V)-540A, 650A, 740A warranty Table of Contents, General Safety Information

Page 3

In addition to these instructions, the equipment shall be installed in accordance with those installation regulations in accordance with those installation regulations in force in the local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made.

In the absence of local codes, the installation must conform with the instructions as outlined in the latest publication of National Fuel Gas Code (NFPA-54/ANSI Z223.1) and National Electric Code (NFPA-70). These manuals can be purchased from the Canadian Standards Association Laboratories, 8501 East Pleasant Valley Road, Cleveland, OH 44131, National Fire Protection Association, 1 Batterymarch Park, Quincy MA 02269.

TABLE OF CONTENTS

 

PAGE

 

PAGE

ROUGH-IN-DIMENSIONS

2

Heater Wiring

19

FOREWORD

2,3

START UP

19

TABLE OF CONTENTS

3

Important

19

GENERAL SAFETY INFORMATION

3

Filling

19

Precautions

3

Purging

19

Liquid Petroleum Models

3

Wiring Diagram

20,21

Chemical Vapor Corrosion

3,4

Lighting and Operating Label

22

Improper Combustion

4

Sequence of Operation

23

EXTENDED NON-USE PERIODS

4

Water Temperature Control

23

Cathodic Protection

4

Adjustment Procedure (Initial Start-Up)

23,24

Insulation Blankets

4

Adjustment Procedure for Fire-Rate, Low Nox and

 

High Altitude Installations

4

 

High Elevation (Fine-Tune)

24-26

FEATURES

4

GENERAL INFORMATION

27

Low Emmission Control

4

Power Burner

27

High Limit Switch (E.C.O.)

4,5

Thermostat

27

Dishwashing Machine Requirement

5

High Limit

27

INSTALLATION INSTRUCTIONS

5

MAINTENANCE

27

Required Ability

5

General

27

Uncrating

5

Maintenance Schedule

27

Locating the Heater

5,6

Electrical Servicing

27

Hard Water

6

Flushing

27

Clearances

6

Draining

28

Air Requirements

6

Sediment Removal

28

Venting

6,7

Lime Scale

28

Vertical Venting - For BTP Models

7

Relief Valve

28,29

Horizontal (Side-wall) Venting - For BTPV Models

7,8

Circulating Pump

29

Direct Venting - For BTPV Models

9-11

Low Emission Power Burner

29

Gas Piping

11-12

Cleaning Flues

29

Gas Meter Size

12

Barometric Draft Control

29

Gas Pressure Regulation

12

Vent System

29

Gas Valves

12,13

Water Line Connections

13

CHECKLIST AND SERVICE INFORMATION

29-30

Thermometers

13

TROUBLESHOOTING

30-32

Relief Valve

13

Replacement Parts

32

INSTALLATION DIAGRAMS

14-17

WARRANTY

33

Manifold Kits

18

NOTES

34,35

GENERAL SAFETY INFORMATION

PRECAUTIONS

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

IF THE UNIT IS EXPOSED TO THE FOLLOWING, DO NOT OPERATE HEATER UNTIL ALL CORRECTIVE STEPS HAVE BEEN MADE BY A QUALIFIED SERVICEMAN.

are different from natural gas models. A natural gas heater will not function safely on LP gas and no attempt should be made to convert a heater from natural gas to LP gas.

BTP(V)-540A, 650A & 740A models are not available for use with Liquefied Petroleum or LP gas. If you have obtained a BTP(V)-540A, 650A or 740A model with the intent to use it with Liquefied Petroleum, LP gas - STOP! Immediately contact your dealer to obtain a correct model.

1.EXTERNAL FIRE.

2.DAMAGE.

3.FIRING WITHOUT WATER.

4.SOOTING.

LIQUID PETROLEUM MODELS

WARNING

Water heaters for propane or liquefied petroleum gas (LPG)

CHEMICAL VAPOR CORROSION

WARNING

CORROSION OF THE FLUEWAYS AND VENT SYSTEM MAY OCCUR IF AIR FOR COMBUSTION CONTAINS CERTAIN CHEMICAL VAPORS. SUCH CORROSION MAY RESULT IN FAILURE AND RISK OF ASPHYXIATION.

Spray can propellants, cleaning solvents, refrigerator and air conditioning refrigerants, swimming pool chemicals, calcium

3

Image 3
Contents Models BTPV-540A, 650A and 740A Installation Operation Maintenance Limited WarrantyForeword ROUGH-IN DimensionsGeneral Safety Information Table of ContentsExtended NON-USE Periods FeaturesUncrating Installation InstructionsDishwashing Machine Requirement Required AbilityVenting Hard WaterClearances AIR RequirementsVent Connections Barometric Draft Control AssemblyVertical Venting for BTP Models Horizontal SIDE-WALL Venting For Btpv ModelsVent Terminal LOCATIONS-EXHAUST Vent System InstallationVent Terminal LOCATIONS-INTAKE Direct Venting for Btpv ModelsDirect Vent System Installation GAS Piping Drain Valve and Access PanelsGAS Valves ANY Supply Pressure Testing Exceeding 1/2 PSIG. GASGAS Meter Size City Gases only GAS Pressure RegulationWater Line Connections Relief ValveSystem Connections Circulating Pump Wiring Diagram Installation DiagramsWiring Diagram for Tempered Water Loop if Used Circulating Pump Wiring Diagram Page Manifold Kits Filling Heater WiringStart UP PurgingPage Page For Your Safety Read Before Lighting Sequence of Operation Adjustment for High Elevation Application Premix LOW NOx Burner Exploded View for BTP Models Premix LOW NOx Burner Exploded View for Btpv Models General Information MaintenanceDraining Sediment RemovalLime Scale Removal Checklist and Service HOT Water Odor TroubleshootingWater is TOO HOT Water Heater Makes SoundsBurner Lockout Once in a While Motor will not RUNGAS Fails to Shut OFF Noisy Burner OperationModel Btpv Limited Warranty Page Page Replacement Parts

BTP(V)-540A, 650A, 740A specifications

A.O. Smith is renowned for its innovative water heating solutions, and the 650A, 740A, and BTP(V)-540A models exemplify this legacy. These water heaters are designed with advanced technology and feature a range of specifications tailored to meet diverse heating needs.

The A.O. Smith 650A model stands out with its efficient design and high-capacity heating capabilities. It is equipped with a powerful heating element that ensures rapid water heating, allowing consumers to enjoy hot water without long waits. The unit's tank is insulated with durable materials, which minimizes heat loss and enhances energy efficiency. Additionally, it incorporates a glass-lined tank that resists corrosion and extends the lifespan of the water heater, making it a reliable choice for households.

Moving on to the 740A model, this unit is designed for larger applications and can accommodate significant hot water demands. Its advanced heating technology includes an impressive recovery rate, which enables it to supply hot water even during peak usage times. The 740A is also equipped with smart diagnostics that monitor the system's performance, ensuring optimal operation and identifying potential issues before they escalate. This feature enhances user convenience and reduces maintenance costs.

The BTP(V)-540A takes efficiency one step further with its unique heat pump technology. It captures ambient heat from the surroundings to heat water, significantly reducing energy consumption compared to traditional electric water heaters. This eco-friendly model is ideal for those looking to lower their energy bills without sacrificing performance. The BTP(V)-540A also features a user-friendly digital display that allows users to easily adjust settings and monitor performance.

In summary, the A.O. Smith 650A, 740A, and BTP(V)-540A models showcase the brand's commitment to quality, efficiency, and innovation. Each model comes with distinct features tailored to different household requirements. With advanced heating technologies, robust construction, and user-friendly interfaces, these water heaters represent some of the best options available in the market for ensuring a reliable hot water supply. A.O. Smith continues to set the bar high in the water heating industry, making these models a smart investment for any home.