A.O. Smith Water Heater installation instructions LP Gas Only, Explosion Hazard

Page 10

LP Gas Only

Explosion Hazard

Have a qualified person make sure L.P. gas pressure does not exceed 13" water column.

Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Liquefied petroleum gas is over 50% heavier than air and in the occurrence of a leak in the system, the gas will settle at floor level. Basements, crawl spaces, closets and areas below ground level will serve as pockets for the accumulation of gas. Before lighting an L.R gas water heater, smell all around the appliance at floor level. If you smell gas, follow the instructions as given in the warning on the front page.

When your L.P. tank runs out of fuel, turn off the gas at all gas appliances including pilot lights. After the tank is refilled, all appliances must be re-lit according to their manufacturer's instructions.

Table 1

Natural Gas Pipe Capacity Table (Cu. Ft./Hr.)

Capacity of gas pipe of different diameters and lengths in cu. ft. per hr. with pressure drop of 0.3 in. and specific gravity of 0.60 (natural gas).

Nominal

Iron Pipe

 

 

 

Length

of Pipe, Feet

 

 

 

 

 

 

Size, in.

10

20

30

40

50

60

70

80

90

100

125

150

175

200

112

132

92

73

63

56

50

46

43

40

38

34

3!

28

26

3/4

278

190

152

130

115

105

96

90

84

79

72

64

59

55

1

520

350

285

245

215

195

180

170

160

150

130

120

110

100

1-1/4

1050

730

590

500

440

400

370

350

320

305

275

250

225

210

1-1/2

1600

1100

890

760

670

610

560

530

490

460

410

380

350

320

After the length of pipe has been determined, select the pipe size which will provide the minimum cubic feet per hour required for the gas input rating of the water heater. By formula:

Cu. Ft. Per Hr. Required=

Gas Input of Water Heater (BTU/HR) Heating Value of Gas (BTU/FT 3)

The gas input of the water heater is marked on the water heater data plate. The heating value of the gas (BTU/FT 3) may be determined by consulting the local natural gas utility.

Table 2

LP Gas Capacity Table

Maximum capacity of pipe in thousands of BTU per hour of undiluted liquefied petroleum gases (at 11 inches water column pressure). Based on a pressure drop of 0.5 inch water column.

Nominallron

Pipe

 

 

 

Length

ofPipe,

Feet

 

 

 

 

 

Size, in.

1__0_____Z0_______5_0_

 

 

7__

.__SD____9_0___l__L0_0___.J25_1__15_D_

1/2

275

189

152

129

114

103

96

89

83

78

69

63

3/4

576

393

315

267

237

217

196

185

173

162

146

132

1

1071

732

590

504

448

409

378

346

322

307

275

252

1-1_

2205

1496

1212

1039

913

834

771

724

677

630

567

511

Example: Input BTU requirement of the water heater 100,000 BTUH.

Total pipe length, 80 feet = 3/4" IPS required.

Additional tables are available in the latest edition of the "National Fuel Gas Code", ANSI Z223.1.

10

Image 10
Contents Installer SmithWater Important Definitions Fire or Explosion Harzard Improper installation and use may result in property damageFire Hazard GET to Know Your Water Heater GAS Models Consumer Information Important Information About This Water HeaterConsumer Responsibilities Location Requirements Site LocationClearances and Accessibility Pmpey Damage HazardGas Requirements Gas Pressure TestingGas Pressure Gas PipingLP Gas Only Explosion HazardCarbon Monoxide Warning Unconfined SpaceConfined Space RoomAll Air from Outdoors All Air from Inside the BuildingLouvers and Grilles Draft Hood Installation PER OpenVent Pipe Size Vent ConnectorsChimney Connection Piping Installation MA,NTA,N\Propey Damage Hazard Closed System/Thermal ExpansionRelief Valve and Pipe Insulation Some Models Temperature and Pressure Relief Valve Explosion HarzardTemperature & Pressure Relief Valve Combination Space Heating/Potable Water SystemSolar Installation AIRWater System Piping Vent Pipe SystemGas Supply and Piping Lighting Instructions BeforeToturnoffgastoappliance ForyoursafetyreadbeforelightingChecking the Draft Burn HazardEmergency Shut Down Water Temperature RegulationBurner Flames White Rodgers ValvesProperty Damage Hazard Operational ConditionsCondensation Anode Rod/Water Odor Routine Preventive MaintenanceDraining and Flushing Manualrelief Replacement PartsRemoving the Burner from the Manifold/ Burner Assembly ThermalReplacing the Pilot/Pilot Tube Assembly Replacing the ThermocoupleExternal Inspection & Cleaning of the Base-Ring Filter Replacing the Manifold/Burner AssemblyCleaning the Combustion Chamber and Flame-arrestor Piezoelectric Igniter System Testing the Igniter SystemRemoving and Replacing the Gas Control Valve/Thermostat FVlR System Operational Checklist Possible CausesProblem Thermostat set too highYES Repair Parts List Listed Parts Kits and Illustrations Page Limited Residential GAS Warranty Conditions and ExceptionsLimitation on Implied Warranties Claim ProcedureInstallation Information Disclaimers

Water Heater specifications

A.O. Smith is a renowned name in the water heating industry, celebrated for its commitment to innovation, quality, and efficiency. Their water heaters are designed to cater to a wide variety of needs, making them suitable for both residential and commercial applications. The main features of A.O. Smith water heaters are tailored to ensure optimal performance, convenience, and reliability.

One of the standout characteristics of A.O. Smith water heaters is their impressive energy efficiency. Many models are equipped with advanced insulation technologies that minimize heat loss, allowing users to save on energy bills while ensuring a consistent supply of hot water. The introduction of high-efficiency gas burners and electric heating elements enhances their energy utilization, which is reflected in their excellent Energy Factor ratings.

A.O. Smith also incorporates smart technology in its water heaters. Many models feature integrated Wi-Fi connectivity, allowing homeowners to monitor and control their water heating system remotely via a smartphone app. This capability enables users to adjust temperature settings, receive maintenance alerts, and track energy usage, providing a new level of convenience and control.

Durability is another hallmark of A.O. Smith water heaters. Constructed with high-quality materials, these units often feature a glass-lined tank that enhances corrosion resistance. Additionally, many models are designed with a robust anode rod that helps prevent rusting, extending the lifespan of the heater and ensuring dependable service for years to come.

Safety features are also a priority for A.O. Smith. Many water heaters come equipped with advanced safety mechanisms, such as automatic shut-off valves, temperature controls, and flame failure detection systems, ensuring safe operation and reducing the risk of accidents.

Different models are available to suit varying space requirements and preferences. A.O. Smith produces traditional tank water heaters as well as modern tankless options, which provide endless hot water on demand, making them ideal for homes needing high hot water consumption. Their versatility guarantees that customers can find the perfect solution tailored to their specific needs.

In conclusion, A.O. Smith water heaters represent a blend of innovation, efficiency, durability, and safety. With various models available that cater to different heating needs and preferences, A.O. Smith continues to remain a trusted choice for consumers seeking reliable hot water solutions.