If the appliance installation includes other relief valves, such as in “remote” storage tanks etc., check their relief valve operation with the same frequency.

CAUTION: Close cold water inlet valve serving heater and open nearby hot water faucet to relieve the pressure in the heater before attempting to remove anode(s) for inspection.

WARNING

THE WATER PASSING OUT OF THE VALVE DURING THIS CHECKING OPERATION MAY BE EXTREMELY HOT. AVOID CONTACT AND DISCHARGE SAFELY TO PREVENT WATER DAMAGE.

If the temperature and pressure relief valve on the heater discharges periodically or continuously, a problem exists. This may be due to unusually high water temperatures or pressures in the system, or to a faulty relief valve. Contact your dealer or a qualified service technician to find the cause of the problem and to correct it. This may also be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct this situation. DO NOT PLUG THE TEMPERATURE AND PRESSURE RELIEF VALVE.

WARNING

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, TURN OFF THE MANUAL GAS CONTROL VALVE TO THE APPLIANCE.

HOT WATER ODOR

On occasion, hot water may develop a strong odor. If this occurs drain the heater completely, flush thoroughly, and refill. If the problem persists, chlorination of the heater and replacement of the factory installed magnesium anodes with aluminum anodes may correct the condition.

Occasionally water softener companies recommend removal of heater anodes for odor reasons.

CAUTION

Unauthorized removal of the anode(s) will void the warranty. For further information contact your dealer.

ANODE ROD INSPECTION

The heater tank is equipped with anode rods to provide corrosion control. At least once a year the anode rods should be checked to determine if replacement is necessary. Initially the anode rods are approximately 7/8" in diameter with a 1/8" diameter steel core wire running down the center of the anode material. THE ANODES SHOULD BE REPLACED when the 1/8" diameter core wire is visible as this means that the anode material has been expended in the control of corrosion.

For models with top inlet and outlet, it is recommended that, before removing the inner cover for cleaning, inspection or removal of inner parts, you obtain two new nipple collars, part no. 74060. The nipple collars on the heater will usually be damaged when removed. New pipe collars will insure that the seal is such as to prevent leakage of flue products when properly installed.

NOTE: Anode rod inspection may need to be made more frequently in areas subject to acid rain that obtains their water supply from surface water as the low pH will accelerate anode activity.

FLUSHING

1.Turn off the heater electrical disconnect switch.

2.Open the drain valve and allow water to flow until it runs clean.

3.Close the drain valve when finished flushing.

4.Turn on the heater electrical disconnect switch.

DRAINING

The heater must be drained if it is to be shut down and exposed to freezing temperatures. Maintenance and service procedures may also require draining the heater.

1.Turn off the heater electrical disconnect switch.

2.Close the cold water inlet valve to heater.

3.Open a nearby hot water faucet to vent the system.

4.Open the heater drain valve.

5.If the heater is being drained for an extended shutdown, it is suggested the drain valve be left open during this period.

Follow FILLING instructions when restoring hot water service.

RECOMMENDED PROCEDURE FOR

PERIODIC REMOVAL OF LIME DEPOSITS FROM TANK TYPE COMMERCIAL WATER HEATERS

The amount of calcium carbonate (lime) released from water is in direct proportion to water temperature and usage, see chart. The higher the water temperature or water usage, the more lime deposits are dropped out of the water. This is the lime scale which forms in pipes, heaters and on cooking utensils.

Lime accumulation not only reduces the life of the equipment but also reduces efficiency of the heater and increases fuel consumption.

The usage of water softening equipment greatly reduces the hardness of the water. However, this equipment does not always remove all of the hardness (lime). For this reason it is recommended that a regular schedule for deliming be maintained.

The time between cleaning will vary from weeks to months depending upon water conditions and usage.

Refer to A. O. Smith booklet, Form No. 4800, entitled “Why? When and How” for detailed description on tank inspection and cleanout. UN•LIME® and the booklet may be obtained through your A. O. Smith dealer or distributor.

27

Image 27
Contents Commercial GAS, GLASS-LINED, TANK-TYPE Water Heater Models BTI 120 Thru 400/AROUGH-IN-DIMENSIONS Front View TOP View Back View ROUGH-IN-DIMENSIONSGasand Electrical Characteristics Foreword Table of ContentsGeneral Safety Information Features High Altitude InstallationsHigh Limit Switch Dishwashing Machine Requirement Electronic Ignition ControlExhaust Inducer Blower Assy Circulating PumpAIR Requirements LevelingClearances Hard WaterMultiple Heater Manifold VentingType B GAS Vent Model BTI-120Model BTI-154 Model BTI-250 Model BTI-275Model BTI-310 System Connections Water Line ConnectionsWater Potable Heating and Space GAS PipingType of GAS GAS Piping and Dirt LEG InstallationGAS Pressure Regulator GAS Meter Size Natural Gases onlySingle Unit Wiring Diagram BTI-120 Through 400A Heater WiringCode Restrictions Installation DIAGRAMS-TOP INLET/OUTLET UsageTube Inlet Installation GeneralHorizontal Storage Tank and Forced Circulation Vertical Storage Tank and Forced CirculationPage Circulating Return Line Connection Installation DIAGRAMS-SIDE INLET/OUTLET UsageHeater with Mixing Valve and Recirculated Sanitizing Loop TWO PRE-HEATERS with Booster Heater Horizontal Storage Tank Manifold Kits Model Dimension aOperation Sequence of Operation What to do if YOU Smell GAS For Your Safety Read Before OperatingIgnitor Assembly Preventive MaintenanceWater Temperature Control Check the Ignitor AssemblyVenting System Remote Storage Tank Temperature ControlGAS Valves Checking the InputDraining HOT Water OdorAnode ROD Inspection FlushingTank Cleanout Procedure Deliming Using FLO-JUG MethodDeliming Solvents Ignition Module System ServiceReplacement Parts System DiagnosticsYES Sequence of Operation Flow ChartOperational Checklist Complaint Cause User ServicemanRemedy Tank Service and Repair ExpensesClaim Procedure Keepthiswarrantypostedadjacenttotheheaterforfuturereference

BTI 120 specifications

The A.O. Smith BTI 120 is a highly efficient and reliable commercial water heater designed to meet the demanding hot water requirements of larger businesses and institutions. As part of A.O. Smith's BTI series, this model is engineered for performance, durability, and energy efficiency, making it an excellent choice for various commercial applications.

One of the standout features of the BTI 120 is its impressive heating capacity. With a maximum output of 120 gallons per hour, it is well-suited for establishments such as restaurants, hotels, and hospitals, where high volumes of hot water are required to ensure smooth operations. The unit is designed with a robust tank that can accommodate up to 120 gallons of hot water at any given time, ensuring that there is always hot water available for use.

In terms of technology, the A.O. Smith BTI 120 incorporates advanced control systems that allow for precise temperature management. The digital display and control panels provide real-time monitoring of the water temperature, ensuring that it meets the specific needs of the business. Additionally, the system features built-in safety controls to prevent overheating and maintain optimal performance, thereby ensuring safety and efficiency.

Energy efficiency is another critical characteristic of the BTI 120. The unit is designed to minimize energy consumption while maximizing heating efficiency. This is achieved through features such as high-quality insulation and the use of advanced heating elements that deliver hot water more quickly and with less energy wastage. As a result, businesses can benefit from lower operating costs and reduced environmental impact.

Durability is a key aspect of the BTI 120, as it is constructed with high-grade materials that are resistant to corrosion and wear. This ensures a long service life and reduces the need for frequent maintenance and replacements. Furthermore, the unit is designed to operate in various environments and withstand the rigors of continuous use.

In summary, the A.O. Smith BTI 120 is a top-tier commercial water heater that combines performance, efficiency, and durability. With its high heating capacity, advanced control systems, energy-saving features, and robust construction, it is an ideal solution for any business requiring a reliable hot water supply. Choosing the BTI 120 means investing in a product that can enhance operational efficiency and contribute to long-term cost savings.