Genie 3630436275 warranty Mounting Area, Check Check Ceiling for Grounded Power Source

Page 5

NOTE

For all types and styles of doors:

If the ceiling in your garage is so low that there is not at least a 3” space above the Header Bracket mounting point, contact a Genie Factory Authorized Dealer.

If a door spring is in the way, place the Header Bracket above the spring.. Do Not move the door spring..

WARNING:

Door springs are under extremely high tension and should be handled ONLY by a trained professional..

CCheck wall for a stud or a solid header at your mark: (If checking a finished wall, a stud finder may be helpful)..

If location is above Header, a 2” x 6” board must be screwed to studs beside your mark with at least two Lag Screws and Flat Washers (not provided)..

Transfer your mark to new mounting board..

Check Step 5: Check Power Head

Mounting Area

Check ceiling or space above where Opener Power Head will be mounted (Figure 5): There must be a 120 Volt grounded outlet or wiring box within 3 feet of Power Head..

Grounded outlet

10’ (7’-6” door)

11’ (8’ door)

Door Center Line

Figure 5 Check Power Head location

AThe measurements above are taken from the garage door centerline toward the rear of the garage..

BFind location of ceiling joist or truss above where Opener Power Head will be and estimate type and quantity of materials needed for your installation (Figure 6A & B)..

MOUNTING EXAMPLES

Standard Straps Extra wood required Perforated Angle Iron

Figure 6A

OPEN CEILINGS Straps and angle iron may attach directly to joists or trusses..

Perforated Straps

FINISHED CEILINGS

Locate ceiling joists or trusses using a stud finder or similar device.

Attach angle iron(not included) to joists or trusses through finish material using Lag Screws..

Figure 6B Mounting methods for open beam or finished ceilings

Check Step 6: Check Ceiling for Grounded Power Source

ACheck that there is a 15 Amp 120 Volt grounded electrical outlet or grounded permanent wiring box (per building code) within 3’ of Opener Power Head: Figure 5

If not, an outlet or wiring box must be installed.. Contact a licensed electrician for installation..

If building codes require permanent wiring, Power Head must be partially disassembled to install appropriate wiring in place of Power Cord.. (See Assembly and Installation Poster..)

NOTE

Permanent wiring must be installed by a Licensed Electrician.. Not all Genie Factory Authorized Dealers

are Licensed Electrician’s.. Contact someone who is a Licensed Electrician..

WARNING:

Do Not use an extension cord! Extension cords can cause dangerous overheating conditions..

Do Not use portable generator! This product is designed to operate using standard house current.. Do Not use alternate power supplies,

Check Step 7: Check Safe-T-Beam®

Mounting Bracket Location

Check for wood garage frame, jamb, or masonry at mounting location (6” above floor) with attachment tabs facing away from garage door (Figure 7)..

AIf you cannot mount Safe-T-Beam® Mounting Bracket to wood frame:

Concrete screws and concrete anchors (not included) must be used to mount Brackets on masonry with attachment tabs facing away from garage door..

Source

 

 

Sensor

 

 

Safe-T-Beam®

Top of

Mounting Bracket

Bracket

 

 

Figure 7

Mounting

6” above

floor

 

Safe-T-Beam®

 

 

 

Components

 

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

5

Image 5
Contents DC Powered Screw Drive Opener Genie Company Limited Warranty Manual 1 Warranty InformationService From Authorized Dealers Entrapment Warning Label To be AdheredInstructions­ Safety FeaturesCheck following items before assembling Opener Tools used in this sectionMounting Bracket Location Check Check Ceiling for Grounded Power SourceMounting Area Check emove xisting arage Door Locks Check Recommended toolsWood for header, ceiling, and/or door braces store Test Opener monthly.. The door Must reverse on contact withAdjustment 1 Adjusting Limit Switches and Force Controls Little effort is required to turn the Force Adjusting KnobsDo Not Unplug the Unit simply wait On pgEach Remote Control must be programmed separately AccessoriesTransmitter Compliance Statement Moving garage door may cause serious injury or deathRemote Control Operation Install Light Bulbs and LensTo Erase All Remotes from Power Head Memory To Replace Remote Control BatterySource Red LED Sensor Green LED Possible Problem Solution Safe-T-Beam System Self-Diagnostic TroubleshootingGenie BLINKS, PauseDoor hardware or rollers may result in a ONE-BLINK signal You See Problem What to Do ReferenceCheck door condition.. Note This Opener is equipped with an OpenerProblem What To Do General Troubleshooting Always Check the Status LED LightOpening Cover May Result in Electric Shock Wiring DiagramPart Name Power Head Assembly Exploded ViewQuantity Hardware Exploded View Las Instrucciones que Ordenan Instructions CommandantOrdering Instructions

3630436275 specifications

The Genie 3630436275 is an innovative piece of equipment that exemplifies cutting-edge technology in the field of aerial work platforms. Engineered with the latest advancements, this versatile lift offers the perfect solution for various construction and maintenance tasks, enabling operators to work safely and efficiently at significant heights.

One of the standout features of the Genie 3630436275 is its impressive working height. With the ability to reach heights that facilitate work on large buildings, infrastructure, and even indoor projects, this lift ensures that users can access challenging spots without compromising safety. The model's compact design allows it to navigate through tight spaces often found in urban construction zones, making it especially suitable for indoor applications as well.

The Genie 3630436275 is equipped with advanced hydraulic systems that provide smooth and responsive lift operation. These mechanisms enable quick ascent and descent, greatly reducing downtime during projects. Additionally, its robust construction guarantees durability and reliability, enabling it to withstand the rigors of continuous use in various environments.

Safety is paramount when it comes to aerial work platforms, and the Genie 3630436275 does not disappoint in this regard. It features multiple safety mechanisms, such as a sturdy guardrail system, emergency stop buttons, and load sensors that ensure operators are working within safe limits. The platform is designed with non-slip surfaces, enhancing grip and stability while working at height.

The technology incorporated into the Genie 3630436275 also includes an intuitive control system that provides operators with precise handling capabilities. The user-friendly interface allows for straightforward control, whether navigating through a job site or setting the lift to the desired height.

Battery-powered options for the Genie 3630436275 further complement its environmentally friendly profile. With quieter operation compared to traditional fuel-powered lifts, it is well-suited for use in noise-sensitive areas or during off-hours work.

In conclusion, the Genie 3630436275 is a versatile, high-performing aerial lift that combines innovative technology, durable construction, and an emphasis on safety. With its array of features, it serves as an essential tool for professionals across various industries, streamlining access to elevated work areas while prioritizing user safety and convenience. This model is an excellent choice for those seeking reliability and efficiency in their aerial work platform solutions.