Genie 3630436275 warranty Genie, Safe-T-Beam System Self-Diagnostic Troubleshooting, BLINKS, Pause

Page 10

MAINTENANCE

AMonthly:

Door springs and door hardware:

Oil door roller, bearings, and hinges using silicone lubricant or light oil..

WARNING

Do not operate door automatically or manually if springs are broken.. Contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE..

Balance Door..

Close door.

Release Magnetic Carriage Assembly from Rail Assembly by pulling down on Emergency Release Knob..

Raise door manually 3’- 4’ and verify that door stays at that position.. See Check Step 2 on page 4..

NOTE

When the door is 3’ - 4’ above the ground, the door should stay open.. Slight movement is acceptable.. If the door moves too much, contact a Genie Factory Authorized Dealer for service or call Customer Service at

1-800-35-GENIE.

Reattach Magnetic Carriage Assembly to Rail Assembly by pulling the Emergency Release Knob toward Power Head..

Close door..

Contact Reverse Test.

Perform Adjustment 2 on page 8..

WARNING

If the door fails to reverse on contact with the board, adjust the Close Force Control as specified in Set Limit Switches and Force Controls on page 7.. If the Opener still fails, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE..

BYearly:

Wipe off old excess lubricant from Drive Screw.

Lubricate Drive Screw with Genie Lubricant (GLU-3)

NOTE

Use ONLY Genie Lubricant (GLU-3).. Other lubricants may damage the Opener..

 

 

Garage

GLU-3

Drive Lubricant

Door Part

 

 

ScrewOpenerGLU-3

 

 

No.

Lubricant

FCC AND IC CERTIFIED

All devices comply with Part 15 of the FCC Rules.. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, includ- ing interference that may cause undesired operation..

Troubleshooting Guide

Safe-T-Beam® System Self-Diagnostic Troubleshooting

Source (Red LED)

Sensor (Green LED)

Possible Problem

Solution

ON

ON

Normal operation

None required

OFF

OFF

• Power Head not powered

• Check breakers, fuses, plugs

• Wiring from Power Head bad

• Check wiring for obvious shorts

 

 

OFF

ON

• Wiring to Source missing or bad

• Check wiring

• Power has been interrupted

• Remove power and reapply

 

 

2 BLINKS, Pause

 

• Beam not aligned

• Check Source, Sensor alignment

(Repeat)

ON

• Beam obstructed

• Check for obstruction

 

 

• Sensor defective

• Contact Customer Service

2 BLINKS, Pause

OFF

• Wire to Sensor missing or bad

• Check wiring

(Repeat)

• Sensor defective

• Contact Customer Service

 

3 BLINKS, Pause

ON

• Sensor receiving interference

• Determine source of interference

(Repeat)

 

• Contact Customer Service

 

 

4 BLINKS, Pause

ON

• Source not sending pulses

• Contact Customer Service

(Repeat)

• Source defective

• Contact Customer Service

 

 

 

 

 

10

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Image 10
Contents DC Powered Screw Drive Opener Service From Authorized Dealers Manual 1 Warranty InformationGenie Company Limited Warranty Entrapment Warning Label To be AdheredSafety Features Instructions­Tools used in this section Check following items before assembling OpenerMounting Area Check Check Ceiling for Grounded Power SourceMounting Bracket Location Wood for header, ceiling, and/or door braces store Check Recommended toolsCheck emove xisting arage Door Locks Test Opener monthly.. The door Must reverse on contact with Do Not Unplug the Unit simply wait Little effort is required to turn the Force Adjusting Knobs Adjustment 1 Adjusting Limit Switches and Force Controls On pgTransmitter Compliance Statement AccessoriesEach Remote Control must be programmed separately Moving garage door may cause serious injury or deathTo Erase All Remotes from Power Head Memory Install Light Bulbs and LensRemote Control Operation To Replace Remote Control BatteryGenie Safe-T-Beam System Self-Diagnostic TroubleshootingSource Red LED Sensor Green LED Possible Problem Solution BLINKS, PauseCheck door condition.. Note This Opener is equipped with an You See Problem What to Do ReferenceDoor hardware or rollers may result in a ONE-BLINK signal OpenerGeneral Troubleshooting Always Check the Status LED Light Problem What To DoWiring Diagram Opening Cover May Result in Electric ShockQuantity Power Head Assembly Exploded ViewPart Name Hardware Exploded View Ordering Instructions Instructions CommandantLas Instrucciones que Ordenan