Graco 3A0019J important safety instructions Fire and Explosion Hazard

Page 3

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

SKIN INJECTION HAZARD

High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

• Do not point gun at anyone or at any part of the body.

Do not put your hand over the spray tip.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Do not spray without tip guard and trigger guard installed.

Engage trigger lock when not spraying.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Do not leave the work area while equipment is energized or under pressure. Turn off all equipment and follow the Pressure Relief Procedure in this manual when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu- facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

3A0019J

3

Image 3
Contents Series Chemical Pumps Important Safety InstructionsModels ContentsFire and Explosion Hazard Moving Parts Hazard Keep Components a and B Separate Isocyanate ConditionsMaterial Self-ignition Moisture Sensitivity of IsocyanatesOutlet Housing D Component Identification40cc pump shown Flushing Pressure Relief ProcedureRequired Tools RepairPump Disassembly Remove throat retainer 16 or 17 or 5cc, 10cc, and 15cc pumps 60cc-160cc pumps Pump AssemblyR2578913a001915h Pump Size Torque 5cc, 10cc, and 15cc Pumps Parts20cc, 25cc, 30cc, 40cc, and 50cc Pumps 60cc, 65cc, 75cc, 80cc, 86cc, 100cc, 120cc, and 160cc Pumps Part Description Qty Pump PartsCylinder O-ring Kits Cylinder KitsCrossover Tube Kits Throat Cartridge Kits Throat Retainer KitsPiston Retainer Kits Seal Kits Displacement Rod Kits Throat Spacer Kits Displacement Rod KitsLength Inlet Outlet Dimensions150 mm Outlet Housing Mounting Hole LayoutTechnical Data Graco Information Graco Standard Warranty