2. Safety instructions

GB

Electrical safety:

DANGER ! Electric shock !

Risk of injury due to electric shock !

Always unplug your Garden Pressure Tank Unit before filling, after operation, when troubleshooting and before carrying out any maintenance work.

Caution: Pursuant to DIN VDE 0100-702 use of the pump near to swimming pools and garden ponds and other similar places is only permissible if the pump is operated via a residual-current device (FI switch) with a residual current rating of ￿ 30 mA.

The pump must be located on solid, even ground, protected from flooding. Take care that the pump cannot fall into water.

As an additional safety device an authorised safety switch can be used.

Please ask your electrician for his advice.

Data indicated on the type plate must match the technical data of the mains supply.

Pursuant to DIN VDE 0620 the power cable as well as any extension cable must not have a smaller diameter than rubber sheathed cables described with letter symbols H07 RNF.

Protect the power cable from heat, oil and sharp edges.

Do not use the power cable for carrying the pump or for unplugging.

In Austria

In Austria the electrical connection must satisfy the ÖVE-EM 42, T2 (2000)/1979 § 22 to § 2022.1. This requires that pumps used for swimming pools and garden ponds may only be powered through an isolating transformer.

Please ask your electrician for his advice.

In Switzerland

In Switzerland portable devices that are used outdoors must be connected through an earth leakage circuit breaker. Mobile appliances that are used outdoors must be connected via a residual-current device.

General Information:

Risk of injury due to hot water !

If the pressure switch is defective and the pressure tank unit runs for an extended period (> 5 min) when the pressure side outlets are closed, the water in the pressure tank unit can become heated so that hot water can emerge from the outlet and cause injuries.

Pump may only run for max. 5 min with the discharge side closed.

If the water supply on the intake side of the pump fails, the water in the pump can heat up so that if water emerges, injuries could be caused by the hot water.

Disconnect pump from the mains, allow water to cool down and ensure the water supply is functioning correctly before starting the pump again.

Before operating the pressure tank unit, first make a visual check to ensure there is no damage to the pressure tank unit (especially regarding power cable and plug).

A damaged pressure tank unit must not be used.

In case of damage, please have the pressure tank unit checked by our GARDENA Service Centre or by an authorised electrician.

Protect the pump from rain. Do not use the pressure tank unit in a wet or moist area.

In order to avoid dry-running of the pressure tank unit, take care that the end of the suction hose is always submerged into the liquid.

The pressure tank unit must not be run dry nor with the stopcock in the suction pipework clo- sed.

Before each operation, fill the pressure tank unit to overflowing with approx. 2 to 3 l of the liquid to be pumped!

Sand and other abrasive substances in the liquid cause increased wear and reduce the pump’s output.

When using the pump for domestic water supply, please adhere to the local water and sewerage regulations. In addition observe the regulations of DIN 1988.

If necessary contact your local water authority.

12

Image 3
Contents Instruções de utilização Bomba doméstica DK Brugsanvisning Liquids pumped Where to use your Gardena Pressure Tank UnitContents Correct useSwitzerland Safety instructionsElectrical safety AustriaOnly be tightened by hand InstallationThis relieves the pump of the weight of the suction hose Connect the hose to the suction sideIntegrated non-return valve will open Close venting Turn rotary switch to RUNOperation Connect hose to the output side NoteStorage MaintenanceClean suction filter StorageTroubleshooting Accessories Warranty Technical dataResponsabilità 3000/4 3000/4 5000/5 4000/5 Características de performance Ydelses karakteristikaUSA