Gardena D-89070 Ulm operating instructions Troubleshooting

Page 7

GB

Cleaning the check valve:

1. Unplug the pump from the mains.

 

2.

Turn the Pressure Tank Unit upside down.

 

3.

Turn the rotary switch

to FILL.

 

4.

If necessary close all the suction side inlets.

 

5.

Open all pressure side outlets, so that the pressure side is

 

 

depressurised.

 

2

6.

Unscrew the drain screw

and drain the water.

 

 

1

Undo screw and slide the clip upwards 1 and to the rear

 

7.

 

 

2 into the bearing groove.

 

8.

Using a suitable tool, unscrew the check valve cover .

 

9.

Remove the valve body

and wash it under running water.

10.Reassemble the check valve in the reverse order.

11.Switch the Pressure Tank Unit back on again

(see 4. Operation).

7. Troubleshooting

DANGER ! Electric shock !

Unplug the cable at the mains before trouble-shooting.

Problem

Probable cause

Remedy

The pump sucks nothing up.

Rotary switch is not turned to

Refill pump and turn rotary

 

 

RUN.

switch to RUN.

 

 

 

 

 

 

The pump is sucking air through

Check all connections and

 

 

a leak at a connection on the

make them air-tight as

 

 

suction side.

necessary.

 

 

 

 

 

 

Pump is not adequately primed

Prime the pump

 

 

with the liquid to be pumped.

(see 4. Operation).

 

 

 

 

 

 

Air cannot escape on the pres-

Open the pressure side

 

 

sure side, because the pressure

outlets.

 

 

side outlets are closed.

 

 

 

 

 

 

 

End of the suction hose is not in

Check the complete suction

 

 

the water, the non-return valve

hose from suction point

 

 

at the end of the suction hose is

through to the pump for leak-

 

 

missing or leaking, the suction

tightness and repair any

 

 

hose is kinked, connections are

leaks as necessary.

 

 

leaking or the suction filter is

 

 

 

blocked.

 

Pump motor does not start

Mains plug not plugged in.

Insert mains plug into a

or stops suddenly during

 

mains socket (230 V AC).

operation.

 

 

Power failure.

Check fuse and cables.

 

 

 

 

Pump impeller is jammed.

Turn the pump impeller motor

 

 

 

shaft with a screwdriver to

 

 

 

free it.

 

 

Overheating due to running dry

Check the water level at the

 

 

or water temperature too high

suction side.

 

 

(Thermal overload switch has

The maximum temperature of

 

 

switched the pump off).

the liquid conveyed should

 

 

 

be (35 °C).

16

Image 7
Contents Instruções de utilização Bomba doméstica DK Brugsanvisning Liquids pumped Where to use your Gardena Pressure Tank UnitContents Correct useSwitzerland Safety instructionsElectrical safety AustriaOnly be tightened by hand InstallationThis relieves the pump of the weight of the suction hose Connect the hose to the suction sideIntegrated non-return valve will open Close venting Turn rotary switch to RUNOperation Connect hose to the output side NoteStorage MaintenanceClean suction filter StorageTroubleshooting Accessories Warranty Technical dataResponsabilità 3000/4 3000/4 5000/5 4000/5 Características de performance Ydelses karakteristikaUSA