5. Storage

Storage:

If there is a risk of frost, the Pressure Tank Unit must be stored

 

where it will not become frozen.

1.Unplug the mains connection for the pump.

Disposal:

(in accordance with directive 20002/96/EC)

2. Turn the rotary switch to FILL.

3. Unscrew the drain screw .

The Pressure Tank Unit will drain down.

4.Store the pressure tank unit in a dry, frost-free place.

Store out of the reach of children.

The unit must not be disposed of with normal household waste but must be disposed of in accordance with local environmental regulations.

GB

6. Maintenance

DANGER ! Electric shock !

Pull out mains plug before undertaking any maintenance.

Clean suction filter:

1.

The rotary switch must be set to RUN.

 

 

If necessary turn the rotary switch to RUN.

 

2.

If necessary, close all the shut-off devices on the intake side.

 

3.

Unscrew and remove cover

 

 

of the filter chamber.

 

4.

Draw out filter unit

 

 

vertically upwards.

 

5.

Hold beaker

firmly, turn

 

 

filter anti-clockwise A and

 

 

draw out B (bayonet fitting).

 

6.

Clean beaker

under running

 

 

water and clean the filter

 

 

e.g. with a soft brush.

 

7.

Refit filter again in reverse

 

 

order.

 

15

Image 6
Contents Instruções de utilização Bomba doméstica DK Brugsanvisning Correct use Where to use your Gardena Pressure Tank UnitContents Liquids pumpedAustria Safety instructionsElectrical safety SwitzerlandConnect the hose to the suction side InstallationThis relieves the pump of the weight of the suction hose Only be tightened by handConnect hose to the output side Note Close venting Turn rotary switch to RUNOperation Integrated non-return valve will openStorage MaintenanceClean suction filter StorageTroubleshooting Accessories Technical data WarrantyResponsabilità 3000/4 Características de performance Ydelses karakteristika 3000/4 5000/5 4000/5USA