Connect hose to the output side: Note:
Use
Clip, Art. no. 7192.
Under no circumstances use these hoses on the suction side.
➔ Connect delivery hose to the delivery side connection.
4. Operation
Connecting the Pressure Tank Unit:
DANGER ! Electric shock !
➔ Before filling the pump, unplug the equipment from the mains.
Warning ! Pump running dry.
➔Fill the pump to the overflow (approx. 2 to 3 litres) with water each time before the pump is switched on.
1. | Unscrew the cover | of the filter chamber by hand. |
2. | Turn the rotary switch | to FILL. |
| The integrated | |
3. | Open the air bleed . |
|
4.Open any
5.Empty any water remaining in the delivery hose so that the air can escape during filling and priming.
6.Slowly por approx 2 to 3 l of the liquid to be pumped throught
| the filler neck | , until it emerges from the air bleed . |
7. | Screw the filter chamber cover closed again, turning by | |
| hand until it stops. | |
8. | Close venting | and turn rotary switch to RUN. |
9.Insert the mains plug into a 230 V mains socket.
CAUTION ! The pump will start immediately !
Once the maximum pressure is reached the pump will switch off automatically. When the pressure falls below the minimum value due to water being drawn off, the pump will switch on again automatically.
The maximum
14