B. SOFT WATER SERVICE and REGENERATION
AUTOMATIC | BYPASS | ELECTRONICS |
During the brining, brine rinse and backwash cycles
of regeneration, HARD water goes through the soft- ener valve and to the house pipes. If a faucet is opened, hard water is there for your needs. Howev-
er, you should not use hotwater, if possible, because the water heater will refill with hard water. The soft-
ener, as factory programmed, regenerates from 2:00 AM to about 4:00 AM, a time when not much water is used.
If you start your day earlier in the morning (prior ro 4:00 AM), you may want to change the recharge
starting time. Set the recharge time to 12:00 AM or
1:00 AM (page
will not refill with hard water if a hot faucet is opened.
Two main parts of the softener's electronics are [] a WATER METER, and [] a COMPUTER.
[] WATER
ener valve outlet. As water flows through the meter,
it sends electric pulses to the computer. The com-
puter changes the pulses to a measure in gallons of water.
[] COMPUTER
faceplate timer circuit board. It is programmed to
know the softener's capacity (how many grains of
hardness minerals it will take out of the water before
a regeneration is needed). When starting the soften-
er, page 1- 4, you set it for the grains per gallon (gpg)
hardness of the water.
To find a regeneration pattern best for your needs,
the computer uses: (1) water usage from the meter,
(2) hardness setting, (3) softener capacity, and (4)
time since the last regeneration. The computer
always adjusts this pattern to your water using
habits. It works toward providing you with soft water for the longest time and at the most efficient salt usage.
Softening capacity is used as hard water goes
through the softener and hardness minerals are
removed. When the computer determines that only enough capacity remains to provide soft water up to
the next regeneration starting time (2:00 AM, or as
otherwise set) it will schedule a regeneration.
RECHARGE TONIGHT displays until the
regeneration begins. When the regeneration begins,
RECHARGE TONIGHT goes off and RECHARGE NOW flashes during the regeneration.
Problems, Questions? Call