Kenmore 625.34847 warranty Care of Your Softener, 3C. Keep the Softener from Freezing

Page 16

SECTION 3

CARE OF YOUR SOFTENER

, i1,1 ul,

iiii ,,11,,i

3C. KEEP THE SOFTENER FROM FREEZING

u Ulll.

ii,

If the softener is installed where it could fi-eeze (summer cabin, lake home, etc_), you must drain all water from it to stop possible freeze damage, To drain the softener:

1.Close the shut-off valve on the house main

water pipe, near the water meter or pressure tank_

2.Open a faucet in the soft water pipes to vent pressure in the softener

m If a single bypass valve is insta!led, move the stem into bypass. See FIG, 12 on page 18 In a 3-valve bypass system, close the inlet and outlet valve and open the bypass valve, If you want water in the house pipes again, reopen the shut-off valve on the main water' pipe,

4.Unplug the transformer at the wall outlet.

5.Remove the salt hole cover and the main cover_ Take off both drain hoses

6.Careful!y remove the large holding clips at the softener" inlet and outlet (see Key No, 61, on page 30) Separate the softener fi'om the adaptors or bypass valve

. Remove the brinewell cover and disconnect the brine valve tubing at the nozzle and venturi assembly (see page 23), Lift the brine valve out of the brinewell Tip the brine valve upside down to drain out water.

DRAIN WATER FROM THE

SOFTENER

___..___---.----

Drain Wood Block

o Looking at FIG 11, lay a piece of 2 inch thick board near the floor drain Move the softener

close to the drain. Slowly and carefully, tip it over until the rim rests on the wood block with the inlet and outlet over the drain Do not

allow the softener's weight to rest on the inlet and outlet fittings or they will break.

QTip the bottom of the softener up a few inches and hold until all water has drained Leave the

softener laying like this until you are ready to use iL Plug the inlet and outlet with rags to keep dirt, bugs, etc, out,

16

Image 16
Contents Demand Water Softeners Sears Installation Policy Sears Installation Warranty WarrantyFacts and Figures to Keep Table of Contents Repair PartsSoftener Start UP Care of Your SoftenerWater Softener START=UP Safety Guides SectionBe sure to restart the water heater See Program the Timer DownTimer SctonProgram SET Water Hardness NumberWater Softener START-UP ADD WaterSeot on ADD SaltRecharge NOW Rechargetonight2B. Soft Water Service and Regeneration ServiceregenerationBrine Rinse Water Flow Through Softener in Service Fill BackwashSoftener 1N Backwash Water Flow Through Softener in Brining Brine Rinse2B, Soft Water Service and Regeneration Automatic BypassPlease see page 9 for Salt Filling DiRECTiONS Keeping the Water Softener Clean Coversnote3C. Keep the Softener from Freezing Care of Your SoftenerDrain Water from Softener Problem Cause Correction Careofyoursoftener4A.DIMENSIONSISPECIFICATIONS Timer SR Code SR22Bypass Valves SINGLE-PLASTICSINGLE-BRASS5A.TROUBLESHOOTING WIRtNG SchematicAutomatic Electronic Diagnostics Manual Initiated Electronic DiagNostics CodeSwitch Displays Valve Cycle Status TroubleshootingSE!TON $ECTNON Manual Advance Regeneration CheckRotary Valve Service Servicing the ValveService Cycle SeotronWater Flow Through the Softener Valve Fill CycleSeotro Brining and Brine Rinse CyclesBackwash Cycle OutletSecthon SERwcETECHINFORMATIONPage KEY Part DescriptionEbrine Valve Assembly EpARPA. .TSSears Water Softeners N0.!NUMBERDESCRIPTION KEY Part Number Description Bypass Installation ValveKEY Part NO. Number Swars

625.34847 specifications

The Kenmore 625.34847 is a prominent air conditioner that offers an impressive combination of efficiency, cooling power, and user-friendly features. It is designed to provide optimal comfort in residential spaces, making it ideal for homeowners seeking reliable climate control during those sweltering summer months.

One of the standout features of the Kenmore 625.34847 is its powerful cooling capacity. With a BTU rating that can efficiently cool rooms of various sizes, this air conditioner is perfect for living rooms, bedrooms, and office spaces. Its ability to quickly lower indoor temperatures ensures a comfortable environment, even on the hottest days.

The Kenmore 625.34847 employs advanced technology to enhance its performance. It utilizes a high-efficiency inverter compressor, which adjusts the cooling output based on the current temperature and the desired settings. This not only provides more precise temperature control but also minimizes energy consumption, making it a great choice for energy-conscious consumers. The unit is designed with an Energy Star rating, indicating that it meets stringent energy efficiency guidelines established by the EPA.

User convenience is another hallmark of the Kenmore 625.34847. It features a digital display and a user-friendly control panel, allowing for easy adjustments to settings such as temperature, fan speed, and mode. The included remote control further enhances usability, enabling users to make adjustments from the comfort of their couches or beds.

With multiple fan speeds and cooling modes, including energy-saving and sleep modes, this air conditioner adapts to the user’s preferences and daily routines. The unit also boasts a robust air filtration system, which captures dust, allergens, and other airborne particles, contributing to better indoor air quality.

Installation is straightforward, and the unit includes a window installation kit, making setup easy for most homeowners. Overall, the Kenmore 625.34847 stands out as a versatile, efficient, and user-friendly air conditioning solution, making it an excellent choice for anyone looking to enhance indoor comfort while keeping energy costs in check. Its combination of features ensures that it meets the demands of modern living while maintaining a commitment to efficiency and quality.