Argosy Research H200HF Series manual H200 Series, H200 Typical Single Tank Installation-Top Mount

Page 8

H200 Series

A. MINERAL TANK: Fiberglass tank with Polyethylene Inner Shell and Fiberglass Roving Manufactured to Operate at 150 psi. NSF Approved.

B.DISTRIBUTOR SYSTEM: Two-Inch Hub & Lateral Dis- tributor for Maximum Service Flow and Minimal Pressure Loss.

C.MINERAL: High Capacity Ion Exchange Resin. Uniform and stable beads assure long life, high salt efficiency, and maximum hardness removal.

D.UNDERBEDDING: Multi-Layered Gravel Underbedding assures full usage of mineral bed and allows for a smooth and constant water flow for service and regeneration.

E.BRINE TANK: Rotationally Molded Polyethylene with Dust-Tight Cover.

F.GRID PLATE: Grid plate allows for dry salt storage. Avail- able in various sizes and heights.

G.OPTIONAL SAFETY BRINE VALVE: Acts as a Secondary Shut-Off for Timed Brine and may be used as a Primary Shut-Off without Timed Brine.

A

GB

E

C

D

F

Figure 1

H200 Typical Single Tank Installation-Top Mount

 

 

 

Bypass Valve

1" MNPT

2” FNPT Inlet &

Inlet

Outlet

Brine Line

 

 

2.5” Victaulic

 

 

 

 

 

2” FNPT Drain &

Brine Tank

 

Isolation Valves

2.5” Victaulic

 

 

 

 

Internal Meter

2” FNPT Outlet &

 

Flex Connectors

 

2.5” Victaulic

 

Figure 2

 

 

Shut-Off Valve

 

 

 

NOTE:

System connections to the tank must accommodate longitudinal movement between side, top and bottom openings, flexibility in piping or flex connectors are recommended.

Red colored piping, fittings, and connectors are for reference only and are not included. Must be furnished by others.

Union type connectors are recommended on the inlet and outlet connections.

1" Brine Line must be hard-piped, secured and supported for proper operation. CPVC or Schedule 80 PVC recommended.

H200 Twin Alternating Tank Installation - Top Mount

Shut-Off Valve

Bypass Valve

 

 

Outlet

 

Inlet

 

MAV Valve*

 

Isolation Valves

Brine Tank(s)

Brine Tank(s)

 

Flex Connectors

See NOTE Figure 2

Shut-Off Valve

Figure 3

8

MAV = Motorized Alternating Valve.

 

Image 8
Contents H200 & H200HF Series Hellenbrand Means Quality and Reliability Page All Diagnostic History screens are resettable Diagnostics 5-B Valve History Screens Modes of Regeneration Meter Initiated OptionsH200 Series H200 Typical Single Tank Installation-Top MountH200 Twin Alternating Tank Installation Top Mount H200 Single Installation Side Mount H200 Twin Alternating Side Mount H200 HF Single Tank Installation H200 HF Twin Alternating InstallationH200 Physical Specifications H200 Series Top Mount DimensionsH200 Series Side Mount Dimensions H200 Capacity RatingsH200HF Capacity Ratings H200HF Physical SpecificationsH200HF Series Side Mount Dimensions-Fiberglass Tanks