Harbor Freight Tools R-410A manual Engineered Features

Page 1

Geo-Trio™ High Efficiency Geothermal/Water Source

Step-Capacity Heat Pump — R-410A

Ground Water Application: Water Temp 40° to 100°

Ground Loop Application: Temp Range 25° to 110°

The Bard Geo-Trio™ Geothermal/Water Source Heat Pump delivers economical year-round comfort by utilizing nature’s most abundant and efficient solar energy collector – the earth. The Geo-Trio™ Series heat pumps are designed for low water flow rates and offer cooling efficiencies up to 29.1 EER and heating efficiencies up to 4.8 COP on ground water, and cooling efficiencies up to 24.9 EER and heating efficiencies up to 4.4 COP on ground loop.

All units are shipped prewired for fast, easy installation in residential or commercial buildings.

TYPICAL INSTALLATION APPLICATIONS Compressor, Blower and A Coil Sections stack vertically for upflow and counterflow installations. Blower and A Coil Sections can be remotely mounted in attics or crawl spaces providing horizontal right or left opportunities.

Engineered Features

Steel Cabinet:

Galvanized 20 gauge zinc coated steel cabinet with baked-on, textured enamel which allows it to withstand 1000 hours of salt spray exposure.

Multi-Capacity Two-Stage:

Simple thermostatic control seamlessly stages the compressor and indoor airflow rate between full and part load capacity operation without cycling the compressor. This helps to maximize comfort, humidity control, energy efficiency and overall reduction in compressor cycling for improved system life.

Step Capacity Compressor: Copeland step-capacity (2-stage) scroll compressors are designed for increased efficiency, quieter operation and improved reliability for longer life.

R-410A Refrigerant:

Designed with R-410A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2010 EPA requirements.

Liquid Line Drier:

Protects system against moisture.

Thermostatic Expansion Valve: For wide range refrigerant control (2-way operation).

High Pressure Switch:

Provides additional protection for the system.

Low Pressure Switch:

Two switches provided. Factory wired switch is for ground water applications, alternate switch is field connected for ground loop applications.

Control Panel:

Mid-level for easy access. Blower section includes transformer and blower control.

High Efficiency Coaxial Water Coil in either Copper or Cupronickel Water to refrigerant coil is completely insulated to prevent frost build-up at low temperature operation.

Indoor Air Coil:

Grooved copper tubing and enhanced louvered aluminum fin for maximum heat transfer and energy efficiency.

Coil coating is black E-Coat electrostatic coating on complete coil.

Cased Indoor Air Coils for Fossil Fuel (Dual Fuel):

Insulated cased coils to fit standard 17.5" and 21" width furnaces.

Lockout Circuit:

Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor.

Variable Speed ECM Blower Motor:

High Efficiency

Soft starting - low noise on start up

Continuous fan - will operate at 50% of rated Stage 2 airflow

Mild Weather Operation:

Part Load Cooling Operation will operate at 20% reduced airflow for the first 5 minutes of operation. This results in 32% increased applied moisture removal during this 5- minute period, and helps humidity control during short-run conditions. This is seamlessly controlled internal of the unit controls with no required user intervention.

Water Connections:

All water connections on outside of cabinet. Brass full swivel double o-ring connection with 1" full flow ports.

Refrigerant Connections:

Special self-sealing fittings are used with 3' line set for stacked upflow or downflow applications, and line sets up to 50' available for horizontal or dual-fuel applications.

Service Access Ports:

Permits service pressure check of discharge and suction pressures.

Filter Rack (Optional):

Accessory kit with 1" filter (reversible for left or right side access for upflow installations).

Accessory Electric Duct Heater Option: 5, 10, 15 and 20KW nominal size. Field installed external to unit. For upflow and horizontal duct installation only.

Optional Accessories:

Room thermostat - Water accessory kit - Waterflow controls.

Domestic Hot Water Heat Exchanger System: Double wall vented heat exchanger and pump with ECM motor and operating controls, factory installed on all 1-phase models.

Hot Water Heating Performance and Operating Cost Savings: The actual amount of hot water (gallons of hot water per day) generated and resultant operating cost savings can vary greatly because of several factors: heat pump system size, hours per day of operation of the heat pump, mode of operation (cooling vs. heating), hot water usage patterns, heat pump water supply system (ground water, ground or pond loop, etc.), and climatic conditions. The gallons of hot water per day are dependent upon the above variables, and in general can range up to 125 gallons per day for a nominal 24,000 BTU heat pump system, and up to 375 gallons per day for a nominal 60,000 BTU heat pump system in the cooling mode, offering a 100% energy savings over conventional electric water heaters. During the winter months when the heat pump is operating in the heating mode, less hot water is available, but at the same time, the electric water heater will consume less electricity.

Form No.

S3423-1112

Supersedes

S3423-912

Page

1 of 28

Image 1
Contents Engineered Features Shipping Weights Fossil Fuel Coils Shipping Weights GT SeriesCross-Reference Table Airflow Corrections Indoor Blower Performance Rated CFMRatings Based on Approved Compressor & GTA-Coil Only Approved Compressor, GTA-Coil & Blower Section CombinationsApproved Compressor and GTA-Coil Ratings Based on Approved Compressor and Fossil Fuel A-Coil For Use with Gas or Oil Furnace as Dual Fuel InstallationCorrection Factors @ Increased Water Flows Optional Field Installed Start Kits for 1-Phase Models Side Filter Rack For Upflow InstallationsOptional Field Installed Start Kit for 1-Phase Models Refrigerant Connections Self-Sealing FittingsGround Loop Service Accessories Ground Loop AccessoriesGround Water/Water Loop Service Accessories Ground Water/Water Loop AccessoriesEvaporator and Blower in Horizontal Position Drain pan kit Model GTHZ-1 TOP Upflow Position Filter Application Table Counterflow Filter Application for All Installation PositionsCooling Full Load GTC36S1 Matched with GTA3600UD1-A CoilTotal GTC48S1 Matched with GTA4860UD1-A Coil GTC48S1 Matched with GTA4860UD1-A Coil GTC60S1 Matched with GTA4860UD1-A Coil GTC60S1 Matched with GTA4860UD1-A Coil Power Heat Total Leaving Power Heat Cooling Full Load Cooling Full Load Total Leaving Total Leaving Power Heat Overflow Main Drain Fossil Fuel ADP Coil Section DimensionsGTA Coil Dimensions If Used Without Cabinet GTA Coil Dimensions if Used Without Cabinet

R-410A specifications

Harbor Freight Tools R-410A is a high-quality refrigerant that has become essential for modern air conditioning systems. Designed specifically for use in HVAC applications, R-410A is a hydrofluorocarbon (HFC) refrigerant that plays a crucial role in energy efficiency and improved environmental performance. One of its standout characteristics is its ability to operate at a higher pressure than older refrigerants like R-22, making it an ideal choice for new systems and retrofits.

One of the main features of Harbor Freight Tools R-410A is its excellent thermodynamic properties, which contribute to improved cooling efficiency. The refrigerant boasts a high latent heat of vaporization, allowing it to absorb and release significant amounts of heat during the compression and evaporation processes. This efficiency translates to lower operational costs and reduced energy consumption, making it a popular choice for environmentally conscious consumers and businesses alike.

In terms of safety, R-410A is non-toxic and non-flammable, addressing concerns associated with certain older refrigerants. This aspect is particularly important in residential and commercial settings, where the safety of occupants is paramount. Furthermore, R-410A has a zero ozone depletion potential (ODP), aligning with global initiatives to phase out substances that are harmful to the atmosphere.

Harbor Freight Tools R-410A is also compatible with various lubricants and doesn't require the use of mineral oil, which is essential when retrofitting older systems. The refrigerant’s unique blend allows for seamless operation in systems designed to operate at high efficiency.

With a boiling point of approximately -51 degrees Celsius, R-410A works effectively in a wide temperature range, making it suitable for various cooling and heating applications. This versatility ensures that users can rely on this refrigerant for both residential air conditioning units and commercial systems alike.

Overall, Harbor Freight Tools R-410A stands out as a modern solution for HVAC needs, combining efficiency, safety, and environmental responsibility. Its innovative characteristics and features make it a go-to choice for both contractors and DIY enthusiasts looking to optimize their air conditioning systems while adhering to current environmental standards. The continued adoption of R-410A underscores the ongoing evolution of the HVAC industry, catering to the needs of a more eco-conscious market.