Harbor Freight Tools R-410A manual Filter Application Table

Page 13

Filter Application Table

Many standard size filters are represented below since there can be a wide variety of possibilities depending upon application position of the heat pump system and the return air duct installation.

 

 

 

Airflow CFM

Airflow CFM

Airflow CFM

Filter Nominal Size

Surface Area FT2

Filter Type

Capability @ 300

Capability @ 500

Capability @ 625

 

 

 

FPM Velocity

FPM Velocity

FPM Velocity

10" X 20" X 1"

1.39

 

415

 

 

 

 

 

 

 

 

12" X 20" X 1"

1.67

 

500

 

 

 

 

 

 

 

 

14" X 20" X 1"

1.94

 

580

 

 

 

 

 

 

 

 

14" X 25" X 1"

2.43

 

730

 

 

 

 

1" Fiberglass Disposable

 

Not Recommended

Not Recommended

16" X 20" X 1"

2.22

670

 

 

 

 

 

 

16" X 25" X 1"

2.78

 

840

 

 

 

 

 

 

 

 

20" X 20" X 1"

2.78

 

840

 

 

 

 

 

 

 

 

20" X 25" X 1"

3.47

 

1050

 

 

 

 

 

 

 

 

24" X 24" X 1"

4.00

 

1200

 

 

10" X 20" X 2"

1.39

 

415

700

 

 

 

 

 

 

 

12" X 24" X 2"

2.00

 

600

1000

 

 

 

 

 

 

 

14" X 20" X 2"

1.94

 

580

975

 

 

 

 

 

 

 

14" X 25" X 2"

2.43

 

730

1215

 

 

 

 

 

 

Not Recommended

16" X 20" X 2"

2.22

2" Std. Fiberglass Disposable

670

1120

 

 

 

 

 

 

16" X 25" X 2"

2.78

 

840

1400

 

 

 

 

 

 

 

20" X 20" X 2"

2.78

 

840

1400

 

 

 

 

 

 

 

20" X 25" X 2"

3.47

 

1050

1750

 

 

 

 

 

 

 

24" X 24" X 2"

4.0

 

1200

2000

 

10" X 20" X 1"

1.39

 

425

700

 

 

 

 

 

 

 

12" X 24" X 1"

2.00

 

600

1000

 

 

 

 

 

 

 

14" X 20" X 1"

1.94

 

590

980

 

 

 

 

 

 

 

14" X 25" X 1"

2.43

 

730

1215

 

 

 

 

 

 

Not Recommended

16" X 20" X 1"

2.22

1" Pleated Filter

670

1115

 

 

 

 

 

 

16" X 25" X 1"

2.78

 

840

1400

 

 

 

 

 

 

 

20" X 20" X 1"

2.78

 

840

1400

 

 

 

 

 

 

 

20" X 25" X 1"

3.47

 

1050

1740

 

 

 

 

 

 

 

24" X 24" X 1"

4.00

 

1200

2000

 

10" X 20" X 2"

1.39

 

425

700

870

 

 

 

 

 

 

12" X 24" X 2"

2.00

 

600

1000

1250

 

 

 

 

 

 

14" X 20" X 2"

1.94

 

590

980

1215

 

 

 

 

 

 

14" X 25" X 2"

2.43

 

730

1215

1520

 

 

2" Pleated Filter

 

 

 

16" X 20" X 2"

2.22

670

1115

1400

 

 

 

 

 

 

16" X 25" X 2"

2.78

 

840

1400

1740

 

 

 

 

 

 

20" X 20" X 2"

2.78

 

840

1400

1740

 

 

 

 

 

 

20" X 25" X 2"

3.47

 

1050

1740

2170

 

 

 

 

 

 

24" X 24" X 2"

4.00

 

1200

2000

2500

 

 

 

 

 

 

12" X 24" X 4"

2

 

600

1000

1250

 

 

 

 

 

 

16" X 20" X 4"

2.22

 

670

1115

1400

 

 

 

 

 

 

20" X 20" X 4"

2.78

4" Pleated Filter

840

1400

1740

 

 

 

 

 

 

20" X 25" X 4"

3.47

 

1050

1740

2170

 

 

 

 

 

 

24" X 24" X 4"

4

 

1200

2000

2500

 

 

 

 

 

 

NOTE: FR23 16x25x1 side filter rack has a washable multi-layer aluminum mesh filter that is rated at 650 FPM maximum.

Form No.

S3423-1112

Supersedes

S3423-912

Page

13 of 28

Image 13
Contents Engineered Features Shipping Weights Fossil Fuel Coils Shipping Weights GT SeriesCross-Reference Table Airflow Corrections Indoor Blower Performance Rated CFMRatings Based on Approved Compressor & GTA-Coil Only Approved Compressor, GTA-Coil & Blower Section CombinationsApproved Compressor and GTA-Coil Ratings Based on Approved Compressor and Fossil Fuel A-Coil For Use with Gas or Oil Furnace as Dual Fuel InstallationCorrection Factors @ Increased Water Flows Optional Field Installed Start Kits for 1-Phase Models Side Filter Rack For Upflow InstallationsOptional Field Installed Start Kit for 1-Phase Models Refrigerant Connections Self-Sealing FittingsGround Loop Service Accessories Ground Loop AccessoriesGround Water/Water Loop Service Accessories Ground Water/Water Loop AccessoriesEvaporator and Blower in Horizontal Position Drain pan kit Model GTHZ-1 TOP Upflow Position Filter Application Table Counterflow Filter Application for All Installation PositionsCooling Full Load GTC36S1 Matched with GTA3600UD1-A CoilTotal GTC48S1 Matched with GTA4860UD1-A Coil GTC48S1 Matched with GTA4860UD1-A Coil GTC60S1 Matched with GTA4860UD1-A Coil GTC60S1 Matched with GTA4860UD1-A Coil Power Heat Total Leaving Power Heat Cooling Full Load Cooling Full Load Total Leaving Total Leaving Power Heat Overflow Main Drain Fossil Fuel ADP Coil Section DimensionsGTA Coil Dimensions If Used Without Cabinet GTA Coil Dimensions if Used Without Cabinet

R-410A specifications

Harbor Freight Tools R-410A is a high-quality refrigerant that has become essential for modern air conditioning systems. Designed specifically for use in HVAC applications, R-410A is a hydrofluorocarbon (HFC) refrigerant that plays a crucial role in energy efficiency and improved environmental performance. One of its standout characteristics is its ability to operate at a higher pressure than older refrigerants like R-22, making it an ideal choice for new systems and retrofits.

One of the main features of Harbor Freight Tools R-410A is its excellent thermodynamic properties, which contribute to improved cooling efficiency. The refrigerant boasts a high latent heat of vaporization, allowing it to absorb and release significant amounts of heat during the compression and evaporation processes. This efficiency translates to lower operational costs and reduced energy consumption, making it a popular choice for environmentally conscious consumers and businesses alike.

In terms of safety, R-410A is non-toxic and non-flammable, addressing concerns associated with certain older refrigerants. This aspect is particularly important in residential and commercial settings, where the safety of occupants is paramount. Furthermore, R-410A has a zero ozone depletion potential (ODP), aligning with global initiatives to phase out substances that are harmful to the atmosphere.

Harbor Freight Tools R-410A is also compatible with various lubricants and doesn't require the use of mineral oil, which is essential when retrofitting older systems. The refrigerant’s unique blend allows for seamless operation in systems designed to operate at high efficiency.

With a boiling point of approximately -51 degrees Celsius, R-410A works effectively in a wide temperature range, making it suitable for various cooling and heating applications. This versatility ensures that users can rely on this refrigerant for both residential air conditioning units and commercial systems alike.

Overall, Harbor Freight Tools R-410A stands out as a modern solution for HVAC needs, combining efficiency, safety, and environmental responsibility. Its innovative characteristics and features make it a go-to choice for both contractors and DIY enthusiasts looking to optimize their air conditioning systems while adhering to current environmental standards. The continued adoption of R-410A underscores the ongoing evolution of the HVAC industry, catering to the needs of a more eco-conscious market.