Harbor Freight Tools R-410A manual Drain pan kit Model GTHZ-1

Page 10

Page

Supersedes

Form No.

10 of 28

S3423-912

S3423-1112

Horizontal, Left Discharge

Return

 

Supply

 

 

Return

 

Evap. Coil

 

 

 

 

Blower Air

 

 

 

 

Secondary

 

 

 

Drain

 

 

 

Main Drain

Main Drain

Refrigerant

Blower in

 

Secondary Drain Connections

Shipped Position

Return

 

<

 

 

 

NOTE: Requires horizontal

 

drain pan kit Model GTHZ-1

 

>

 

 

Blower in

 

 

 

Horizontal, Right Discharge

 

Shipped Position

 

 

Return

 

 

Supply

Evap. Coil

Blower Air

Main Drain

Refrigerant

Blower in

 

Secondary Drain Connections

Alternate Position

Air Filter Required on Return Air Side for All Installations

Upflow installations can use (1) FR23 (16x25x1) or field supplied equivalent on either side of the blower section. Use of (2) on both sides is optional.

Bottom return for upflow and top return for downflow must be field supplied.

For horizontal attic or crawl space installations filter arrangement must be field supplied & should be located in readily accessible location for the user.

See additional information on Pages 13 & 14.

Supply

Return

Upflow

Counterflow

Position

Position

 

Refrigerant

 

 

Connections

 

Evap. Coil

Secondary

Evap. Coil

 

Drain

 

 

Main Drain

 

 

Return

 

Blower Air

 

Blower

 

 

Air

 

Blower in

 

 

Alternate Position

 

Return

 

Supply

 

 

 

 

Optional Top

Cond. Coil

 

 

Water Out

 

Model GTLID

 

 

Desuper.

 

 

Water Out

 

 

Desuper.

 

Refrigerant

 

Connections

Water In

 

 

 

Cond. Coil

Water In

Remote Condenser Section

MIS-2826

Image 10
Contents Engineered Features Shipping Weights Fossil Fuel Coils Shipping Weights GT SeriesCross-Reference Table Indoor Blower Performance Rated CFM Airflow CorrectionsRatings Based on Approved Compressor & GTA-Coil Only Approved Compressor, GTA-Coil & Blower Section CombinationsApproved Compressor and GTA-Coil Ratings Based on Approved Compressor and Fossil Fuel A-Coil For Use with Gas or Oil Furnace as Dual Fuel InstallationCorrection Factors @ Increased Water Flows Optional Field Installed Start Kit for 1-Phase Models Side Filter Rack For Upflow InstallationsOptional Field Installed Start Kits for 1-Phase Models Refrigerant Connections Self-Sealing FittingsGround Loop Accessories Ground Loop Service AccessoriesGround Water/Water Loop Accessories Ground Water/Water Loop Service AccessoriesEvaporator and Blower in Horizontal Position Drain pan kit Model GTHZ-1 TOP Upflow Position Filter Application Table Filter Application for All Installation Positions CounterflowGTC36S1 Matched with GTA3600UD1-A Coil Cooling Full LoadTotal GTC48S1 Matched with GTA4860UD1-A Coil GTC48S1 Matched with GTA4860UD1-A Coil GTC60S1 Matched with GTA4860UD1-A Coil GTC60S1 Matched with GTA4860UD1-A Coil Power Heat Total Leaving Power Heat Cooling Full Load Cooling Full Load Total Leaving Total Leaving Power Heat Fossil Fuel ADP Coil Section Dimensions Overflow Main DrainGTA Coil Dimensions if Used Without Cabinet GTA Coil Dimensions If Used Without Cabinet

R-410A specifications

Harbor Freight Tools R-410A is a high-quality refrigerant that has become essential for modern air conditioning systems. Designed specifically for use in HVAC applications, R-410A is a hydrofluorocarbon (HFC) refrigerant that plays a crucial role in energy efficiency and improved environmental performance. One of its standout characteristics is its ability to operate at a higher pressure than older refrigerants like R-22, making it an ideal choice for new systems and retrofits.

One of the main features of Harbor Freight Tools R-410A is its excellent thermodynamic properties, which contribute to improved cooling efficiency. The refrigerant boasts a high latent heat of vaporization, allowing it to absorb and release significant amounts of heat during the compression and evaporation processes. This efficiency translates to lower operational costs and reduced energy consumption, making it a popular choice for environmentally conscious consumers and businesses alike.

In terms of safety, R-410A is non-toxic and non-flammable, addressing concerns associated with certain older refrigerants. This aspect is particularly important in residential and commercial settings, where the safety of occupants is paramount. Furthermore, R-410A has a zero ozone depletion potential (ODP), aligning with global initiatives to phase out substances that are harmful to the atmosphere.

Harbor Freight Tools R-410A is also compatible with various lubricants and doesn't require the use of mineral oil, which is essential when retrofitting older systems. The refrigerant’s unique blend allows for seamless operation in systems designed to operate at high efficiency.

With a boiling point of approximately -51 degrees Celsius, R-410A works effectively in a wide temperature range, making it suitable for various cooling and heating applications. This versatility ensures that users can rely on this refrigerant for both residential air conditioning units and commercial systems alike.

Overall, Harbor Freight Tools R-410A stands out as a modern solution for HVAC needs, combining efficiency, safety, and environmental responsibility. Its innovative characteristics and features make it a go-to choice for both contractors and DIY enthusiasts looking to optimize their air conditioning systems while adhering to current environmental standards. The continued adoption of R-410A underscores the ongoing evolution of the HVAC industry, catering to the needs of a more eco-conscious market.