| Express® Lavatory System |
Installation Instructions - For Service Only | |
|
|
Metering Air Valve Maintenance
Metering Air Valve Repair Kits and Parts List
VALVE SEAT
LOWER VALVE BODY
CENTER HOLE
RUBBER DIAPHRAGM
PLASTIC DISK
STAINLESS STEEL DISK
SPRING
LOCKWASHER
PARTS INCLUDED
IN KIT
REPAIR KIT
(Note: This repair kit also includes kit
SCREW
Metering Air Valve Troubleshooting
Problem: Water is dripping from the streamformers
Cause: Debris on valve seat or orifices.
Solution: Clean and inspect the valve seat.
1.Remove screws and disassemble metering valve.
2.Clean the valve seat and inspect for deep gouges or scratches. Replace if necessary.
3.Remove all debris that may be clogging center hole of plastic diaphragm assembly.
4.Remove any debris clogging the
Metering Air Valve Troubleshooting continued . . .
Bradley Corporation • | 5/11/04 | 17 |