Step 3: Installing bowl assembly

IMPORTANT: Moving and positioning the bowl will require more than one person.

Note: Refer to Figure 5 below when installing the bowl assembly.

1.With someone to assist you, place the bowl assembly squarely onto the frame.

2.Attach the front of the bowl assembly to the frame using the four 1/4"-20 x 3/8" pan-head screws and washers provided. Do not tighten bolts at this time.

IMPORTANT: When bolting the bowl assembly to the frame and wall, do not overtighten bolts. Overtightening bolts can damage the Terreon® material.

3.After the bowl assembly is attached to the frame, use two 3/8" bolts and washers (supplied by the installer) to bolt the bowl to the wall anchors.

4.Tighten the screws installed in procedure #2 above to secure the bowl assembly to the frame.

Do not overtighten.

BACK VIEW

3/8" BOLT AND WASHER

3/8" BOLT AND WASHER

BOWL

ASSEMBLY

FRAME

 

 

1/4"-20 X 3/8"

 

 

PAN HEAD

 

 

SCREWS AND

Figure 5

 

WASHERS

 

 

 

 

 

Installation Instructions continue . . .

8

5/11/04

Bradley Corporation • 215-1238 Rev. C; EN 03-813

Image 8
Contents Table of Contents Standard and Juvenile HeightPre-Installation Information Supplies required for installationBarrier-free and ADA compliant standard height mounting Barrier-free and ADA compliant juvenile height mountingDimensions continue Standard Height Juvenile Height Installation Instructions Installation Instructions continue SS-3/AST/STD Express Lavatory System Standard Height RoughSS-3/AST/JUV Express Lavatory System Juvenile Height Mounting frame to wall Do not overtighten Connecting supply Connecting plastic tubing Completing installation Cleaning and Maintenance Instructions Terreon and panel maintenanceCleaning Panel cleaningSoap Dispenser Maintenance Fill soap dispensersCheck Valve Troubleshooting Cleaning InstructionsIf water just dribbles or does not flow from sprayhead If water sprayhead delivers all hot or cold waterOptional Stop/Strainer/Check Valve Assembly of ComponentsPaneling Drain Assembly Other Replacement PartsPushbutton assembly Metering Air Valve Maintenance Metering Air Valve TroubleshootingMetering Air Valve Repair Kits and Parts List Problem Water is dripping from the streamformersProblem Valve will not shut off Problem Valve will not turn onProblem Timing can not be adjusted for more than 5 seconds Problem Pushbutton does not work properlyService Suggestions Vernatherm Mixing Valve Maintenance and ServiceMaintenance Instructions