Bradley Smoker MG-2/TT installation instructions Connecting electrical and supply tubing

Page 12

Express® Lavatory System - MG-Series with TouchTime® Control

 

MG-2/TT

Installation Instructions

Installation Instructions continued . . .

Step 7: Connecting electrical and supply tubing

WARNING: MG-2/TT must be connected to 24 VAC Class II plug-in transformer provided. Connection to 110 VAC may cause personal injury and/or damage to electronics. Connection of leads other than shown may cause permanent damage to the switch.

1.Insert the two sprayhead supply tubes into the two solenoid tube connectors by loosening the compression nut and firmly pushing the tubing into the connector until the tubes are fully seated, then re-tighten the compression nut (hand-tight plus two full turns with a wrench) (see Figure 7).

2.Connect the wires per the wiring diagram shown below.

3.Align the mounting screws with slots on the frame. Valve bracket slides down to lock into place.

4.Turn on the water supply to the MG-2/TT Express® and check for leaks.

5.Turn on the electrical power, trigger the TouchTime® push buttons and check for proper function (the timing is electronically controlled and set at 15 seconds).

IMPORTANT: The Vernatherm™ valve is NOT factory-preset. Upon installation, the valve temperature must be checked and adjusted to assure delivery of safe water temperature. Water in excess of 110°F (43°C) may cause scalding.

6.Check the temperature when approximately1.0 GPM water flow is reached and adjust if necessary (the range of the valve is 95°F–115°F (35°C–43°C). To adjust the temperature, first loosen the temperature locking nut with a wrench. Then using a blade screwdriver, turn the adjustment stem counterclockwise to increase the temperature or clockwise to decrease the temperature. Once desired temperature is reached, tighten the nut to prevent temperature change.

7.Reinstall panel to frame with the five Torx-head screws provided (see Figure 3 on page 8).

NOTE: Push button activation takes place only when released, (prevents “hold open” activation).

 

TRANSFORMER

 

 

 

S83-134

 

 

 

 

COMPRESSION

 

 

 

NUT

 

 

 

B BLACK

G BROWN

 

 

LEFT GRAY

 

 

RED

LEFT GREEN

 

 

SUPPLY

 

 

 

TUBE

 

 

 

 

RIGHT GRAY

LEFT

 

 

 

 

 

RIGHT GREEN

BUTTON

 

 

 

 

 

LEFT

LEFT

 

 

GRAY

GREEN

 

GREEN

 

 

 

SUPPLY

 

 

 

TUBE

 

 

 

 

A BLACK

F BROWN

 

H BROWN

 

 

 

F BROWN

 

 

 

G BROWN

 

 

 

E BROWN

VERNATHERM

 

 

D BLACK

THERMOSTATIC

 

 

MIXING VALVE

 

 

 

 

 

C BLACK

 

 

 

B BLACK

 

RIGHT

 

A BLACK

 

BUTTON

 

 

 

Figure 7

 

RIGHT

RIGHT

 

GRAY

GREEN

 

 

 

12

2/8/07

Bradley Corporation • 215-1480 Rev. E; EN 06-915

Image 12 Contents
Table of Contents System MG-Series With TouchTime ControlPre-Installation Information MG-2/TT Express Lavatory System Dimensions 749 445Dimensions TAS Juvenile HeightInstallation Instructions Standard Height MountingJuvenile Height Mounting Rough in supplies and optional hot water heaterBradley Corporation 215-1480 Rev. E EN Rough in wall anchors and electrical outlet Mount frame to wall Front ViewInstall bowl assembly Do not overtightenConnecting supply Hot Cold SuppliesSingle Tempered Supply Connecting optional hot water heater Screws AS ShownConnecting electrical and supply tubing Cleaning and Maintenance Instructions Terreon and panel maintenanceStainless Steel Access Panel cleaning Terreon Bowl, Sprayhead and Pedestal End Cap cleaningAssembly of Components Sensor assembly and solenoid valve access To access solenoidsOther replacement parts TouchTime and Aerator/Access Plate AssembliesTroubleshooting Solenoid Valve VAC Solenoid Valve S07-067 closed body and S07-067A thru body Thermostatic Mixing Valve Maintenance and Troubleshooting Problem Limited water flowProblem External leaks in the system Vernatherm Thermostatic Mixing Valve S01-524 Repair Kit S65-259