Step 2: Rough in wall anchors and electrical outlet

IMPORTANT: Turn OFF electrical power to the outlet when installing the Express® Lavatory System.

1.Install a 110 volt GFI protected electrical outlet per local code at the location shown in Figure 2.

2.Install six 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations marked (ref. location “B” shown in Figure 1, 1a or 1b on pages 5-6).

NOTE: The dimensions for the wall anchors at location “A” are for reference only.

3.On the back of the bowl, measure the distance between the 3/4" bowl mounting holes. Divide this measurement in half. Measure and mark this dimension on the wall to the left of the centerline and to the right of the centerline. Install two 3/8" wall anchors with a minimum pull- out rating of 1,000 lbs. (supplied by installer) at the locations marked (ref. location “A” shown in Figure 1, 1a or 1b on pages 5-6).

NOTE: The anchors will be used to mount the Express® MG-2/IR bowl and frame to the wall.

1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY.

STUB OUT 2"

1-1/2" NPT DRAIN

 

 

 

 

 

110 VOLT GFCI

 

 

 

 

 

 

 

 

STUB OUT 2"

 

 

 

 

ELECTRICAL OUTLET

 

 

 

 

 

 

TRANSFORMER

LOCATION

Figure 2

Bradley Corporation • 215-1480 Rev. E; EN 06-915

2/8/07

7

Image 7 Contents
System MG-Series With TouchTime Control Table of ContentsPre-Installation Information 749 445 MG-2/TT Express Lavatory System DimensionsTAS Juvenile Height DimensionsRough in supplies and optional hot water heater Installation InstructionsStandard Height Mounting Juvenile Height MountingBradley Corporation 215-1480 Rev. E EN Rough in wall anchors and electrical outlet Front View Mount frame to wallDo not overtighten Install bowl assemblyHot Cold Supplies Connecting supplySingle Tempered Supply Screws AS Shown Connecting optional hot water heaterConnecting electrical and supply tubing Terreon Bowl, Sprayhead and Pedestal End Cap cleaning Cleaning and Maintenance InstructionsTerreon and panel maintenance Stainless Steel Access Panel cleaningAssembly of Components To access solenoids Sensor assembly and solenoid valve accessTouchTime and Aerator/Access Plate Assemblies Other replacement partsTroubleshooting Solenoid Valve VAC Solenoid Valve S07-067 closed body and S07-067A thru body Problem Limited water flow Thermostatic Mixing Valve Maintenance and TroubleshootingProblem External leaks in the system Repair Kit S65-259 Vernatherm Thermostatic Mixing Valve S01-524