SAFETY PRECAUTIONS

CAUTION

Do not operate the unit at low outside temperature (less than 14°F) in the cooling mode.

In the cooling mode, if the unit is operated at low outside temperature (less than 14°F), water condensed in the air conditioner may drop and wet or damage furniture, etc.

Do not use the unit for special purposes.

Do not use this air conditioner to preserve precision devices, food, animals, plants and art objects.

This may cause deterioration of quality, etc.

Do not put a stove, etc. where they are exposed to direct airflow.

This may cause imperfect combustion.

When the unit is to be cleaned, switch it off and turn off the breaker.

• Since the fan rotates at high speed during operation, this may cause an injury.

When the unit is not going to be used for a long time, turn off the breaker.

Otherwise, dirt may collect and this may cause a fire.

Replace the 2 batteries of the remote controller with new ones of same type.

Using an old battery together with a new one may result in heat generation, leakage or an explosion.

If liquid from the batteries gets onto your skin or clothes, wash it well with clean water.

If liquid from the batteries gets into your eyes, wash them well with clean water and consult a doctor at

once.

Ventilate well in using the unit with a stove, etc.

An oxygen shortage may occur.

Do not operate switches with wet hands.

This may cause an electric shock.

Do not clean the air conditioner with water or put a vase or glass on it.

Water may enter the unit and degrade the insulation. This may cause an electric shock.

Do not step or put anything on the indoor/outdoor unit.

• This may cause an injury, etc. if you or something falls down.

For installation

WARNING

Consult your dealer for installation of the air conditioner. Since special techniques and work are required,

installation should not be done by the customer. If this is done incorrectly, it may cause a fire, an electric shock, injury or water leaking.

Do not install the unit where flammable gas could leak.

If gas leaks and collects around the unit, it may cause an explosion.

CAUTION

Ground the unit.

• Do not connect the ground to a gas pipe, water pipe, lightning rod or the ground of a telephone. If the grounding is incorrect, it may cause an electric shock.

Install a Ground Fault Interrupt (GFI) circuit breaker depending on the place where the air condi- tioner is to be installed (humid places, etc.).

If the Ground Fault Interrupt (GFI) circuit breaker is not installed, it may cause an electric shock.

Drain should be fully drained.

If the drainage route is incomplete, water may drop from the unit. This may wet and damage the furniture.

Image 5
Contents Operating Instructions Manual DE Instrucciones Índice ContentsSafety Precautions Do not pull the power supply cord Do not scratch or process the power supply cord, etcDo not turn the breaker off/on during operation Do not put a vase or glass on the indoor unitFor installation Outdoor unit Name of Each PartIndoor unit Open the front lid Remote controllerAuto restart function Preparation Before OperationBreaker for the air conditioner Turn the breaker onPress the Reset button How to set the batteries and the current timePress the Clock set button Current timeCase of Emergency Cool Mode Emergency Operation switch twiceEach time the Emergency Operation switch is Pressed, the unit will operate in order of EmerTo start operation FEEL... Auto OperationTo stop operation Description of Auto Restart FunctionDetails of auto operation Description of I FEEL... modeDetails of operation Select the operation mode by pressing the Mode button To select the COOL, DRY or FAN modeWhen the set temperature is to be changed Manual Operation COOL, DRY, FANHorizontal AIR Flow blowing range AIR Flow Velocity and Direction AdjustmentAuto air flow direction control operation Powerful mode Powerful OperationPress the button Operation Vane button is availableEcono Cool Operation What is Econo COOL?To release the Econo Cool operation Press the Econo Cool buttonHow to set the on timer How to set the OFF timer Timer Operation ON/OFF TimerTo release the on timer To release the OFF timerWhen the air conditioner is to be used again When it is not going to be used for a long timeClean the air filter and install it in the indoor unit Turn off the breakerBefore starting maintenance MaintenanceCleaning the indoor unit Clean the unit using a soft dry clothCleaning the air filter about once every 2 weeks Cleaning the AIR Filter CatechinInstall the air filter What is Catechin air filter?Air cleaning filter replacement About once every year Replacement of the AIR Cleaning FilterRemove the air cleaning filter blue bellows type Install the air filter and securely close the front panelCleaning the air cleaning filter about once every 3 months Cleaning the AIR Cleaning FilterWhen a power failure oc Mote control signalQuestion Check points or Remedy Air conditioner cannot Be operatedHink That Trouble has Occurred Electrical work INSTALLATION, Relocation and InspectionInstallation place Operating sound considerations Inspection and maintenanceRelocation DisposalSpecifications are subject to change without notice