Electrolux EOG 10000 user manual Important Safety Requirements, Provision for Ventilation

Page 21

electrolux 21

Important Safety Requirements

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations (current addition) and the I.E.E. Wiring Regulations. Detailed recommendations are contained in the following British Standard Codes of Practice - B.S. 6172, B.S. 5440: Part 2 and B.S. 6891: Current Editions.

For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S. 813 Current Editions and the ETCI Rules for Electrical Installations.

Provision for Ventilation

This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in accordance with the current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation.

The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2 Current Edition. All rooms require an openable window or equivalent and some rooms will require a permanent vent as well. For room volumes up to 5m3 an air vent 100cm2 is required; for room volumes between 5m3 and 10m3, an air vent with a minimum area of 50cm2 is required. If the room has a door which opens directly to the outside, no air vent is required. For room volumes that exceed 11m3 no air vent is required.

If there are other fuel burning appliances in the same room, B.S. 5440: Part. 2: Current Editions should be consulted to determine the requisite air vent requirements.

For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I.S. 813 Current Editions Table Four.

Location of appliance

The appliance may be located in a kitchen, a kitchen/diner or bedsitting room but not in a bathroom, shower room or bedroom.

It is essential that there is a minimum clearance of 4mm between the top surface of the appliance and the inside top of the cabinet. The unit must be fitted into a cabinet conforming to dimensions given in these pages.

For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S 813 Current Edition Section 7- Permitted Locations of Appliance.

This oven unit may be used in a Built-in or a Built-under situation (see relevant diagrams). If the appliance is to be built- under a hob, it is recommended that the hob be installed before the oven unit.

Image 21
Contents IE GB Page Welcome to the world of Electrolux Guide to using the user instructions ContentsOperation InstallationCustomer Service People SafetyDescription of the Appliance Oven accessoriesControls Mains on indicatorOven function control knob Minute minderBefore using the Oven for the first time How to use the Gas Oven Using the OvenHow to use the Gas Grill Oven safety deviceGas Grill safety device Hints and TipsOn Roasting Cooking timesGas Oven Cooking Baking and Toasting TableFood Grill GrillingCleaning and Maintenance Cleaning materialsExternal cleaning Cleaning the Oven Door Oven CavityOvenShelvesandShelfSupports Page Replacing The Oven Light If Something is Wrong Problem SolutionDimensions of the recess Technical DataHeating element ratings OvenProvision for Ventilation Important Safety RequirementsConnectingtotheelectricalsupply Instructions for the InstallerTerminal block For Uk use onlyFor Europe use only Gas Connection Connecting the to the gas supplyElectrolux Gas Grill Burner Data Gas Oven Burner DataConversion from Natural to LPG Gas Replacement of gas oven burner injectorReplacement of Gas Type Label Replacement of gas grill burner injectorMinimum level adjustment of gas oven burner Instructions for Building Oven dimensions Fig. a Instructions for BuildingOpen the oven door Securing the Appliance to the CabinetService and Spare Parts Guarantee/Customer ServiceCustomer Care European GuaranteePage Page 35694-4802