22electrolux
Instructions for the Installer
Installation and connection must be done in compliance with the regulations in force. Any interventions must be carried out when the appliance is switched off. Only accredited engineers may work on the appliance.
The manufacturer disclaims any liability if the safety measures are not observed.
Connectingtotheelectricalsupply
Before connecting to the electrical supply, please make sure:
-The fuse and the domestic electrical installation must be designed for the max. load of the appliance (see rating plate).
-The domestic electrical installation must be equipped with a proper earth connection in accordance with the regulations in force.
-The socket or the
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow- green earth wire at any point. The earth wire should be 2 cm longer than the live and neutral wires.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more
Live wire
Neutral wire
Earth wire