24electrolux
Gas Connection
The use of rubber flexible hoses is not permitted.
Connecting the to the gas supply
The use of rubber flexible hoses is not permitted.
The gas supply connection ramp is located in the upper side of the oven, right behind the control panel.
To carry out the gas connection:
1.Partially insert the oven in the recess (about 30 cm.) and operate on the connection ramp from above. The gas connection can be carried out according to one of the following procedures:
A)connection with flexible metallic pipes (*) (with maximum length up to 2 metres only) — screw the feed pipe to the 1/2“ connection ramp, inserting the supplied gasket between the pipe and the ramp;
B)connection with rigid metallic pipe (soft copper - minimum diameter: 8 mm) — insert the copper pipe into the connection ramp after fitting the proper nut and olive onto the copper pipe using a male / female adapter (not supplied).
2.Tighten the nuts by means of a 22 mm spanner. Care must be taken to keep the ramp in position and not to cause any stress to the gas supply circuit.
3.Completely insert the oven in the recess and secure it as indicated in the relevant paragraph.
4.Check the perfect sealing of the connection using leak detection fluid.
A) View | flexible |
from | metallic pipe(*) |
above | gasket |
|
gas supply ramp
control panel
(*) For mainland Europe only
B)View | rigid metallic pipe |
from | male/femaleadapter |
above | olive |
| |
nut |
|
| gas supply ramp |
control panel
View |
from |
above |
nut |
gas supply ramp |
control panel |