12 Installing the hood
Ceiling ducting
•Use the template previously installed to prepare a 8 - ½” hole in the ceiling for ductwork.
50” max extension
10’ = 120” Ceiling Height
35” (Minimum Installation Height)
RANGE
36”
When the Island is installed in a 10’ Ceiling, 35” is the closest distance we can have from
the cooking surface. 35” is the recommended height
TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN YOUR HOME ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED.
Failure to do so can result in death or electrical shock.
•Remove junction box cover and knockout on the top left side.
Knockout
Junction box cover
30” min extension
8’ = 96” Ceiling Height
30” (Maximum Installation Height)
RANGE
36”
When the Island is installed in an 8’ Ceiling, 30” is the longest distance we can have from the cooking surface. 30” is the recommended height 24” - 30” for electrical cooking surface
Making the electrical connections
Electrical Shock Hazard
Warning: turn off power at the service panel before wiring this unit.
120 V AC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE.
•If not already done, install 1/2” conduit connector in j- box.
NOTE: This connector is not included with vent hood.
Metal electrical conduit
House wiring
UL listed wire nut
•Run black (live), white (neutral), and green (earth) wires (# 14 AWG) according to the National Electrical Code or CSA Standards and local codes and ordinances in 1/2” conduit from power supply to j- box.
•Connect black, white, and green wires from power supply to black, white, and green/yellow wires in j - box respectively.
•These connections should be done always making reference to the electrical diagram found inside the hood.
•Close j - box cover and reapply screws.