Temperature inside the freezer
To ensure that foodstuff will keep for a long time, be sure that the temperature inside the freezer is -18°C or below.
Please note, however, that the energy consumption increases as the temperature decreases.
The built-in temperature display shows the warmest temperature inside the freezer. If the temperature is measured using a thermometer, put it between the products since this will reflect the real temperature in the frozen products. It is normal that the built-in temperature display shows a temperature slightly above that measured in other ways.
Switching off
To switch off, push the ON/OFF button. This will result in a countdown from "3" to "1" taking place in the temperature display. On reaching "1" the freezer will switch off. The temperature display will go off.
Note:
The appliance cannot be switched on or off if unplugged, or if there is no power being supplied to it. Following connection to the mains power supply, the appliance returns to the same operating state as before the interruption of main power.
If the freezer is turned off, the refrigerator will also turn off. E.g. while defrosting the freezer.
Temperature alarm
If the temperature rises above -12°C (temperature setting between -15°C and -24°C) or above than -3°C (temperature setting between -6°C and -14°C), the red warning lamp flashes
and an audible alarm sounds. The temperature display will then start to flash.
To switch off the alarm:
Press the alarm shut-off button to switch off the audible alarm. The temperature display will stop flashing. The red warning lamp goes out when the temperature inside the freezer again falls below -11°C (temperature setting between -15°C and -24°C) or colder than -2°C (temperature setting between -6°C and -14°C).
Find out what caused the alarm. See the chapter "Something not working".
+ -11 -
ACTION FREEZE
Temperature memory
The temperature memory shows when an alarm has been triggered in the cabinet.
The temperature memory operates as follows:
When the temperature inside the freezer again falls below -11°C (temperature setting between -15°C and -24°C) or colder than -2°C (temperature setting between -6°C and -14°C) the audible alarm stops. The temperature display and the red warning lamp will flash to indicate than an alarm was triggered. When the alarm shut-off button is pressed, the display then displays the warmest temperature inside the cabinet during the alarm phase and the display stops flashing. By referring to the temperature display indication, it is possible to decide whether or not to discard the products inside the freezer.