hints for test institutes | electrolux 35 |
Hints for test institutes
Testing in accordance with EN 60704 must be carried out with appliance fully loaded and using the test programme (see "Consumption values").
Test in accordance with EN 50242 must be carried out when the salt container and rinse aid dispenser have been filled with salt and rinse aid respectively and using the test programme (see "Consumption values").
Full load: 9 standard place settings
Amount of detergent required:
Rinse aid setting:
5 g + 20 g (Type B)
position 4 (Type III)
Arrangement upper | Arrangement upper |
basket without smaller | basket with smaller bowl |
bowl and | and |
Arrangement cutlery
basket
Cup racks: position A
Arrangement lower
basket