Symptom | Solution | |
| If the door seal is not airtight (probably | |
| after reversing the door) apply warm air | |
| to the non sealing area using a hair dryer | |
Excessive build up of frost. | set to a gentle heat. (do not use a fan | |
| heater for this purpose). This will make | |
| the rubber more supple and allow it to | |
| revert to its original shape. | |
Noise | Refer to Normal Operating Sounds | |
The compressor does not start | This is normal, the compressor starts after | |
immediately after changing the | ||
a period of time. | ||
temperature setting. | ||
| ||
|
|
If after the above checks there is still a fault, call your local AEG Service Force Centre.
Please note that proof of purchase is required for
Technical Terminology
•Refrigerant
Liquids that can be used to a generate a cooling effect are known as refrigerants. They have a relatively low
•Refrigerant Circuit
Closed circulation system that contains the refrigerant. The refrigerant circuit comprises primarily of an evaporator, a compressor, a condenser and pipe work.
•Evaporator
The refrigerant is evaporated in the evaporator. Similar to all other liquids, refrigerant requires heat to evaporate. This heat is removed from the interior of the appliance, as a result the interior is cooled.
The evaporator is therefore located inside the appliance or placed in foam immediately behind the inner wall and thus not visible.
40 | 818 18 |