Outlet hole - Only for models DF 6260, DF
•When used as an extractor unit, the hood must be fitted with a 150mm diameter hose.
Only for model DF 6260 - DF 6260- ml/1: Should there already be a pipe
of diameter 125 mm that ducts to |
|
| |
the outside through the walls or roof, |
|
| |
it is possible to use the 150/125 mm |
|
| |
reduction flange provided. In this |
|
| |
case the hood will be slightly more |
|
| |
noisy. |
|
| |
Fix the flange on the hood outlet | Fig. 8a | Fig. 8b | |
hole, using 2 screws. Fig. 8a. | |||
|
| ||
Filter version only |
|
|
•Fix the deflector to the flange. Fig. 8b.
Outlet hole - Only for model DF
•When used as an extractor unit, the hood must be fitted with a 120mm diameter hose.
•The dimensions and position of the air outlet are given in figure 9.
•Fix the flange supplied as kit onto the exit hole (bayonet fixture).
•Using the adapter, Ø100, Ø110 and Ø125 mm exhausting pipes can be used.
Ø125 mm exhausting hose: insert the adapter on the flange and remove, using a proper tool, the upper unused Ø 100 and Ø 110 mm rings of the adapter.
Ø110 mm exhausting pipe: same procedure, but removing the Ø 100 mm ring only.
Ø100 mm exhausting pipe: apply the adapter on the flange.
A
Fig. 9
Fig. 10