For the installer
•Only for model DF6160: when used as an extractor unit, the hood must be fitted with a 120mm diameter hose.
•Only for models DF 6260 - DF
Only for model DF 6260 - DF
•When installing the hood, make sure you observe the following minimum distance from the top edge of the
cooking hob/ring surfaces: |
|
electric cookers | 430 mm |
gas cookers | 650 mm |
If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.
•The national Standard on
•The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which
•The air outlet installation must comply with the regulations laid down by the relevant local authorities.
•When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approxi- mately the same as the outlet hole.
•National and regional building regulations impose a number of restrictions on using hoods and
•Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately
•If you have any doubts, contact the relevant controlling authority or building inspector’s office.
•Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of
63