Lifebreath 155ECM Partially Dedicated System, Installation Diagrams, Return Air, Cool Air Return

Models: 200MAX RX 155MAX RX 155ECM

1 36
Download 36 pages 8.13 Kb
Page 25
Image 25
Installation Diagrams

Installation Diagrams

Example diagram only - duct configuration may change depending on model

Partially Dedicated System

Partially Dedicated SystemATTENTION

Duct configuration may change depending on the model. See Specifications for your unit.

DIRECT CONNECTION of the SUPPLY AIR STREAM to the FURNACE COLD AIR RETURN

(Stale air drawn from key areas of home)

EXHAUST AIR from various parts of home.

i.e. bathrooms (if required), kitchens (if required).

Outdoors

NOTES:

Return Air

3' min.

recommended

Cool Air

Return

*Unit is normally balanced on HIGH speed

Forced Air

with furnace blower ON.

Furnace

 

1.Furnace blower may be required to operate when HRV/ERV is on to provide good air distribution.

2.Weatherhood arrangement is for drawing purposes only. 6' (2 m) minimum separation required. 18" (460 mm) above grade minimum.

3.Due to the differences in pressure between the HRV/ERV and the equipment it is being connected to, the HRV/ERV's airflow must be confirmed on site, using the balancing procedure found in the installation manual.

25

Page 25
Image 25
Lifebreath 155ECM Partially Dedicated System, Installation Diagrams, Stale air drawn from key areas of home, Return Air