Emerson 3700, 3350 installation instructions Dimensions conduit openings view, Cable lengths

Page 6

Figure 4. Dimensions – conduit openings view

inches

 

2 x 2 13/17

1 7/8

(71)

(mm)

 

(48)

 

 

2 x 15/16

 

 

(24)

 

Case ground

 

 

5 x 3/4–14 NPT

 

 

or

 

 

5 x M20 x 1.5 – 6H

 

 

10 3/8

(265)

7 1/2

(191)

5 3/4

(147)

Mounting surface

Cable lengths

Maximum cable length from the sensor to the Model 3700 transmitter depends on the installation type and cable type:

4-wire remote transmitter: see Figure 5, then refer to Table 1 for maximum length of the 4-wire cable.

Remote core processor with remote transmitter: see Figure 6, then refer to Table 1 for maximum length of the 4-wire cable and the 9-wire cable.

If you are installing the Model 3350 applications peripheral in combination with a transmitter, the maximum cable length from the transmitter’s frequency output to the Model 3350’s frequency input is 500 feet (150 meters).

5

Image 6
Contents Model 3700 Transmitter MVD or Model 3350 Peripheral Before YOU Begin European installations Installation kitEnvironmental requirements DimensionsChoosing a location Visibility of tagsDimensions face view Dimensions conduit openings view Cable lengthsWire remote transmitter Maximum cable lengthsPreparing conduit openings for Atex Zone Orienting the Model 3350/3700 optionalMounting the applications platform Mounting to a flat surfaceConnecting input and output wiring Mounting the core processorWiring terminals Input/output wiring terminalsWiring terminal labels Connecting the Model 3700 to the sensorInstallation options Wiring instructions for 4-wire remote installationsWire cable to Model 3700 standard core processor Page Gland nut Shielded heat shrink completely covers exposed drain wires Reinstall and tighten the core processor lid Wire cable to core processor Connecting power supply wiring Page Page Page 20001008