Emerson manual Transducer Block Channel Definitions, Channel Definitions for the 848T

Page 38

Rosemount 848T

Reference Manual

00809-0100-4697, Rev EA October 2011

Transducer Block Channel Definitions

Table 3-8. Channel Definitions for the 848T

Figure 3-1. Transducer Block Data Flow

The 848T supports multiple sensor inputs. Each input has a channel assigned to it allowing an AI or MAI Function Blocks to be linked to that input. The channels for the 848T are as follows:

Channel

Description

 

Channel

Description

1

Sensor One

 

16

Sensor 3 Deviation

2

Sensor Two

 

17

Sensor 4 Deviation

3

Sensor Three

 

18

Sensor 5 Deviation

4

Sensor Four

 

19

Sensor 6 Deviation

5

Sensor Five

 

20

Sensor 7 Deviation

6

Sensor Six

 

21

Sensor 8 Deviation

7

Sensor Seven

 

22

Sensor 1 Rate Change

8

Sensor Eight

 

23

Sensor 2 Rate Change

9

Differential Sensor 1

 

24

Sensor 3 Rate Change

10

Differential Sensor 2

 

25

Sensor 4 Rate Change

11

Differential Sensor 3

 

26

Sensor 5 Rate Change

12

Differential Sensor 4

 

27

Sensor 6 Rate Change

13

Body Temperature

 

28

Sensor 7 Rate Change

14

Sensor 1 Deviation

 

29

Sensor 8 Rate Change

15

Sensor 2 Deviation

 

 

 

 

Linearization

Temperature Compensation

Units/Ranging

 

Channel1

S1

 

 

Channel

S2

A/D

 

2

Signal

 

Channel

S3

Conversion

 

3

 

 

Channel

S4

 

 

 

 

 

4

 

 

 

 

 

Channel

S5

CJC

 

 

 

 

5

 

 

 

Damping

Channel

 

 

 

 

 

Channel6

S6

 

Diagnostics

 

Measurement

7

S7

 

 

Channel

 

 

 

Validation

S8

 

 

 

 

 

8

 

 

 

 

 

Channel

DS1

 

 

 

 

 

9

 

 

 

 

 

Channel

DS2

 

 

 

 

 

10

 

 

 

 

 

Channel

 

 

 

 

 

 

11

DS3

 

 

 

 

 

Channel

DS4

 

 

 

 

 

12

 

 

 

 

 

Channel

BT

 

 

 

 

 

13

Transducer Block Errors

The following conditions are reported in the BLOCK_ERR and XD_ERROR parameters.

3-16

Image 38
Contents Reference Manual 00809-0100-4697, Rev EA OctoberPage Rosemount 848T High Density Temperature Transmitter with Customer Central National Response Center InternationalPage Table of Contents Appendix a Operation MaintenanceSection TOC-2Process leaks could result in death or serious injury Safety MessagesSection Introduction Electrical shock could cause death or serious injuryOverview Fieldbus host or configuration toolMaintenance of the Rosemount 848T Temperature Transmitter TransmitterService Support Rosemount 848T Section Installation Safety Messages MountingMounting to a DIN Rail Without an Enclosure Mounting to a Panel with a Junction BoxMounting to a 2-in. Pipe Stand Aluminum/Plastic Junction Box Stainless Steel Junction BoxConnections WiringSpur Signal Wiring Devices 1 through Leads and terminalsAnalog Inputs RTD or Ohm InputsThermocouple or Millivolt Inputs Ohm resistor in the loop when switched to the left ConnectorsPower Supply Analog InputConnections Power SupplySurges/Transients Shielded Wire GroundingMA loop 848T Power Supply Sensor Wires Shield ground pointsTransmitter Enclosure optional Fieldbus busSwitch is not functional SwitchesSimulate Enable SecurityTransmitter Tag TaggingCommissioning Tag Sensor TagUsing Conduit Entries InstallationUsing Cable Glands Section Configuration Standard ConfigurationTransmitter Configuration Custom Configuration Methods Rosemount 848T Function Common Configurations for High Density ApplicationsTypical Profiling Application BlockMeasuring Temperature Points Individually Monitoring Application with a Single SelectionMultiple Analog Input or Analog Input Block Configuration Number Parameter Description Block ConfigurationResource Block 00809-0100-4697, Rev EA October Resource Block Parameters Startwithdefaults SaveconfignowSaveconfigblocks FailedenableAutomatic Auto Block ErrorsModes Block is processing its normal background memory checksPlantWeb Alerts Out of Service OOSAlarm Detection Status Handling00809-0100-4697, Rev EA October Failure Alarms FailedmaskAlarm Maintenance Alarms/Priority AlarmAdvisory Alarms Alarm Type Active Event Recommended Action Recommended Actions for PlantWeb AlertsRESOURCE.RBSFTWRREVALL Transducer BlocksRESOURCE.HARDWAREREV, Channel Definitions for the 848T Transducer Block ErrorsTransducer Block Channel Definitions Channel DescriptionTransducer Block Modes 00809-0100-4697, Rev EA October Block/Transducer ErrorTransducer Block Alarm Detection Block outputs reflect the analog input measurementSENSOR3CONFIG SENSOR1CONFIGSENSOR2CONFIG SENSOR4CONFIGChanging the Sensor Configuration in the Transducer Block Transducer Block Sub-Parameter Tables 11. Xderror Sub-Parameter Structure12. Sensorconfig Sub-Parameter Structure 15. Calstatus Structure 13. Sensorstatus Sub-Parameter Structure14. Sensorcal Sub-Parameter Structure 16. Transducer Status Sub-Parameter StructureStructure StructureDual Sensor Status Table Structure Parameter Description 20. Validation Config Sub-Parameter StructureSensor Calibration in the Sensor Transducer Block Rosemount 848T Foundation Operation and MaintenanceFoundation Fieldbus Information Commissioning Addressing Sensor Check Hardware MaintenanceRestart with Defaults Restart Processor cyclingSymptom Possible Cause Corrective Action TroubleshootingTransducer Block Troubleshooting Symptom Possible Causes Corrective ActionFunctional Specifications Appendix a Reference DataBackup Link Active Scheduler LAS Update TimeAlarms Transient ProtectionPhysical Specifications Performance Specifications Function BlocksAccuracy Sensor Option Sensor Reference 3-Wire RTDsAccuracy for Differential Configurations Input RangesSensor Option Alarm Levels Accuracy Analog Sensors 4-20mAAmbient Temperature Effect Rosemount 848T Dimensional DrawingsAmbient Temperature Notes Examples Top ViewFront View Side View Stainless Steel Junction Box-Cable Gland option code JS2Side View Front View Stainless Steel Junction Box-Conduit Entry option code JS3 Side ViewStainless Steel Junction Box Style JS Mounting OptionsAluminum/Plastic Junction Box Styles JA and JP Front View Side ViewOrdering Information OptionsConduit Electrical Connector Standard Software Configuration StandardSpecial Temperature Test Expanded Enclosure Options StandardRosemount 848T Hazardous Locations Certificates Table B-2. Entity Parameters for Non Incendive Field WiringAppendix B Product Certificates North American ApprovalsPower/Bus Canadian Standards Association CSA Certifications Atex Certifications Power/Bus SensorEuropean Approvals Special Conditions for Safe UseCi = Li = Rosemount 848T Special Conditions of Safe Use IECEx CertificationsRosemount 848T Parameters Terminals of power/loop China NEPSICertificationsJapanese Certifications Intrinsically Safe and NON-INCENDIVE Installations Installation Drawings Figure B-1. FM Intrinsic Safety/ Fisco 00809-0100-4697, Rev EA Rosemount 848T Figure B-2. CSA Intrinsic Safety/ Fisco Rosemount 848T Rosemount 848T Appendix C Foundation fieldbus Technology Overview Function BlocksSnap InputOutput Linkages StatusResource Blocks Device Descriptions Block OperationInstrument- Specific Function Blocks Alerts Transducer BlocksFieldbus Link Network CommunicationLink Active Scheduler LAS LAS Parameters MID x ST DataPublisher/Subscriber Backup LASAddressing Scheduled Transfers Report DistributionDevice Device Y Device Z Unscheduled TransfersSchedule Function Block Scheduling Number Parameter Units Description Appendix D Function BlocksAnalog Input AI Function Block OUTOutscale AlarmhysXdscale IooptsFunctionalitySimulation OUT mode in manOUT mode in auto 63% of ChangeDirect Signal ConversionFiltering IndirectIndirect Square Root ConditionsValue of the block output OUT may be set manually Table D-3. Alarm Priority LevelsManual Man BAD if Limited Uncertain if in Manual modeAdvanced Features Uncertain if LimitedXdblock AI Block TroubleshootingApplication Information HIHILIMIT, LolimitMultiple Analog Input MAI Function Block Table D-4. Multiple Analog Input Function Block ParametersCAPSTDDEV1 Figure D-4. Multiple Analog Input Function Block Schematic SimulateTable D-5. Blockerr Conditions Option in Manual or Out of Service mode onlyDevices such as flowmeters Block output OUT may be set manually MAI Block Troubleshooting IN1 IN2 IN3 IN4 IN5 IN6 IN7 Input Selector Function BlockTable D-6. Input Selector Function Block Parameters OUT OutrangeSelected SelecttypeMingood OpselectAlarm OUT INn DISABLEnMode Logic Selection FunctionalityTable D-8. Alarm Priority Levels OUT reflects the selected valueBlock Execution Use Uncertain as GoodIsel Block Troubleshooting Index NumericsAlarm Detection Configuration Errors Modes AutomaticMaintalarms Troubleshooting Errors Modes AutomaticPage Rosemount Inc Pacific Private Limited

848T specifications

The Emerson 848T is a state-of-the-art temperature transmitter designed for accurate and reliable temperature measurement in various industrial applications. This device has gained recognition for its advanced features and robust performance, making it a popular choice among engineers and technicians in the field.

One of the key highlights of the Emerson 848T is its unique dual-channel capability, which allows it to seamlessly monitor two temperature sources simultaneously. This functionality is particularly beneficial in processes where multiple temperature points need to be assessed, optimizing efficiency and reducing the need for additional equipment. It supports various sensor types, including thermocouples, RTDs, and resistance temperature detectors, making it versatile for different applications.

The 848T is equipped with sophisticated digital processing technology, which enhances its accuracy and stability. It features a 24-bit analog-to-digital converter, ensuring precise measurement and minimizing drift over time. Moreover, the device boasts a wide operating temperature range, accommodating ambient conditions from -40°C to 85°C. This durability makes it suitable for harsh environments commonly encountered in industries such as oil and gas, pharmaceuticals, and power generation.

Another significant characteristic of the Emerson 848T is its configurable output options. Users can choose from a range of output signals, including 4-20 mA, which provides a standard interface for integration into existing control systems. Additionally, it offers a HART communication protocol, allowing for easy configuration, calibration, and diagnostics through a digital interface. This feature enhances the transmitter's usability, enabling operators to perform adjustments without direct access to the device.

The device is designed with user-friendliness in mind. Its intuitive setup procedure and robust graphical user interface simplify the commissioning process, ensuring that even those new to the technology can easily navigate the system. An integrated LCD display provides real-time readings and status information, facilitating monitoring at a glance.

In summary, the Emerson 848T temperature transmitter combines reliable performance, user-friendly design, and advanced digital technologies. Its dual-channel capability, wide sensor compatibility, and adjustable output options make it an essential tool for achieving precise temperature measurements in various industrial settings. With these compelling features, the Emerson 848T stands out as a leading choice for professionals seeking accuracy and efficiency in their temperature monitoring applications.