4.After 1 minute check that the flame cov- ers the full width of the burner and is sta- ble.
5.Set the oven control to Mk 2, close the oven door and check that after about 10 minutes the flame size has reduced.
6.Turn off the control and check that the oven flames go out.
electrolux 25
To set the time of day
Please refer to the Timer section.
General information
Instruct the user on how to use the appliance and its ignition system.
Refer the user to the wording on the inside cover which gives advice on the safe opera- tion of the appliance.
Technical data
Dimensions
Height
Width
Depth
Weight
900 mm (nominal)
600 mm (nominal)
600 mm (to front of door panel)
66 Kg Net
Space for fixing at hotplate level 2mm mini- mum clearance.
Space for fixing above hotplate level See im- portant note 'Location of Appliance'. Minimum space above hoptplate 750mm (If cooker hood is fitted refer to the cooker hood installations.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel).
Loading info : Gas hob
Connections
Gas connection:- Rear left hand side of ap- pliance at hotplate level Rc ½ (½" B.S.P. fe- male)
Electrical connection:- 230 - 240 V 50 Hz Mains connected at rear centre of appliance using at least 6mm2 multi core PVC insulated cable.
Natural Gas
Heat input
Injector Marking L.P. Gas Heat input Injector Marking
R.H.F |
| R.H.R |
1.0kW (3412 Btu/ |
| 1.9kW (6483 Btu/ |
h)h)
070 |
| 096 |
R.H.F |
| R.H.R |
1.0kW |
| 2.0kW |
050 (71.8g/h) |
| 071 (136.5g/h) |
|
|
|
L.H.R | L.H.F |
1.9kW (6483 Btu/ | 3.4kW (11600 |
h)Btu/h)
096 | 136 |
L.H.R | L.H.F |
2.0kW | 3.4kW |
071 (136.5g/h) | 093 (244.12g/h) |
|
|
Loading info : Grill
Heat input
Injector Marking
Loading info : Top oven
Heat input
Injector Marking
Dual control
Natural Gas
2.7kW (9212Btu/h) 120
Natural Gas
1.9kW (6483 Btu/h) 099 50
L.P. Gas
2.7kW (194g/h) 95
L.P. Gas
1.9kW (136.5g/h) 070 38