Malfunction |
| Possible Cause |
| Remedy |
|
|
|
|
|
Unusual noises.
The compressor does not start immediately after changing the temperature setting.
Water on the floor or on sto- rage shelves.
Appliance is not level.
The appliance is touching the wall or other objects.
This is normal, no error has occurred.
Water drain hole is blocked.
Readjust the feet.
Move the appliance slightly.
The compressor starts after a period of time.
See the "Cleaning and Care" section.
If, after carrying out the necessary checks there is still a fault with your appliance please contact your local AEG Service Force Centre.
In guarantee customers should ensure that the suggested checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown.
Please note that proof of purchase is required for any
Changing the light bulb
Warning! There is a risk of electric shocks! Before changing the light bulb, switch off the appliance and unplug it, or pull the fuse or the circuit breaker.
Light bulb data: replace the lamp with one of the same power (the maximum power is shown on the light diffuser).
1. To switch off the appliance, press the button “B”.
2.Unplug the mains plug.
3. To change the light bulb press on the rear hook and at the same time slide the cover in the direction indicated by the arrow.
4.Change the defective light bulb.
5.Refit the light bulb cover.
6.Put the refrigerator back into opera- tion.
20