Gas connection
Connecting the appliance to the gas supply
The use of rubber flexible hoses is not permitted.
The gas supply connection ramp is located in the upper side of the oven, right behind the control panel.
To carry out the gas connection:
1.Partially insert the oven in the recess (about 30 cm.) and operate on the connection ramp from above. The gas connection can be carried out according to one of the following procedures:
A)connection with flexible metallic pipes (*) (with maximum length up to 2 metres only) — screw the feed pipe to the 1/2“ connection ramp, inserting the supplied gasket between the pipe and the ramp;
B)connection with rigid metallic pipe (soft copper - minimum diameter:
2.Tighten the nuts by means of a 22 mm spanner. Care must be taken to keep the ramp in position and not to cause any stress to the gas supply circuit.
3.Completely insert the oven in the recess and secure it as indicated in the relevant paragraph.
4.Check the perfect sealing of the connection using leak detection fluid. Never use a flame for the
Check the gas supply ramp and the gas connection pipe are not squeezed while the oven is positioned into the recess.
The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. Ensure that the kitchen is well ventilated: keep natural ventilation holes open or install a mechanical ventilation device (mechanical extractor hood).
Prolonged intensive use of the appliance may call for additional ventilation, for example opening a window, or more effective ventilation, for example increasing the level of mechanical ventilation where present.
A) | View | flexible |
from | metallic pipe(*) | |
| above |
|
|
| gasket |
|
| gas supply ramp |
| control panel |
|
(*) For mainland Europe only
B) | View | rigid metallic pipe |
from | male/female adapter | |
above | ||
|
| olive |
| nut |
|
|
| gas supply ramp |
| control panel |
|
View |
from |
above |
nut |
gas supply ramp |
control panel |