Conversion from Natural to LPG Gas
IMPORTANT
The replacement/conversion from Natural to LPG should only be undertaken by a competent and qualified engineer.
It is important to note that this model is designed for use with natural gas but can be converted for use with LPG providing the correct injectors are fitted. The gas rate is adjusted to suit.
Replacement of gas oven burner injector
To replace the gas burner oven injector, follow this procedure:
1.Remove the bottom plate of the oven (“A”) to access the gas oven burner;
2. Undo the two fixing screws (“C”) which keep the gas oven burner in place
3. Gently slide the oven gas burner off the injector support (“D”) and slowly move it to the left hand side. Check that the burner bush does not slip off the burner mouthpiece, and take care not to cause stress to the spark plug connection wire (“E”) and the thermocouple (“F”) conductor;
3.With a 7 mm socket spanner unscrew and remove the gas burner injector (“D”), and replace it with the required one (see Table on this page);
4. Reassemble the burner following the same procedure backwards.
The oven burner does not require any primary air regulation.
Gas Oven Burner Data
GAS | INJECTOR | NOMINAL | NOMINAL GAS | REDUCED | NOMINAL | |
TYPE | MARK | GAS | FLOW IN | GAS | NEEDLE | GAS |
| 1/100 mm | POWER |
| POWER | (1/100 mm) | PRESSURE |
| m3/h g/h | |||||
|
| (kW) | (kW) |
| (mbar) |
Natural Gas | 114 | 2,7 | 0,257 | - | 1,0 | Reg. | 20 | |
(G20) | ||||||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
LPG | 78 | 2,5 | - | 182 | 1,0 | 52 | ||
(G30/G31) | ||||||||
|
|
|
|
|
|
|
17