Electrolux EOG 6000 Instructions for the Installer, Important Safety Requirements, Building, Oven

Page 13

Instructions for the Installer

Technical Data

 

Oven

 

 

Model Name: EOG 6000

 

 

 

 

Oven Burner

2,700 W (Natural gas)

 

 

APPLIANCE GAS SUPPLY:

Natural Gas G20 20mbar

 

2,500 W (LPG)

Gas Grill Burner

1,900

W

APPLIANCE CATEGORY:

II2H3+

Oven light

15

W

 

 

Cabinet Dimensions

Cooling fan

25

W

Total electric rating

40

W

 

 

Minimum aperture height

580 mm

Supply voltage (50 Hz)

230 V

 

 

 

Minimum aperturedepth

550 mm

 

 

 

Minimum aperture width

560 mm

 

 

 

Important Safety Requirements

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations (current addition) and the I.E.E. Wiring Regulations. Detailed recommendations are contained in the following British Standard Codes of Practice - B.S. 6172, B.S. 5440: Part 2 and B.S. 6891: Current Editions.

For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S. 813 Current Editions and the ETCI Rules for Electrical Installations.

Provision for Ventilation

This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in accordance with the current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation.

The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2 Current Edition. All rooms require an openable window or equivalent and some rooms will require a permanent vent as well. For room volumes up to 5m3 an air vent 100cm2 is required; for room volumes between 5m3 and 10m3, an air vent with a minimum area of 50cm2 is required. If the room has a door which opens directly to the outside, no air vent is required. For room volumes that exceed 11m3 no air vent is required.

If there are other fuel burning appliances in the same room, B.S. 5440: Part. 2: Current Editions should be consulted to determine the requisite air vent requirements.

For appliances installed in the Republic of Ireland please refer to the NSAI-Domestic Gas Installation I.S. 813 Current Editions Table Four.

Building in

Location of appliance

The appliance may be located in a kitchen, a kitchen/ diner or bedsitting room but not in a bathroom, shower room or bedroom.

It is essential that there is a minimum clearance of 4mm between the top surface of the appliance and the inside top of the cabinet. The unit must be fitted into a cabinet conforming to dimensions given in these pages.

For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S 813 Current Edition Section 7- Permitted Locations of Appliance.

This oven unit may be used in a Built-in or a Built-under situation (see relevant diagrams). If the appliance is to be built-under a hob, it is recommended that the hob be installed before the oven unit.

13

Image 13
Contents Instruction Booklet Page ImportantSafetyInformation Contents Description of the Appliance Oven accessoriesControls Before the First Use Using the OvenCondensation and steam Oven safety device Using the Gas OvenCooking Chart Hints and TipsGas Grill safety device Using the Gas GrillCleaning the Oven Something Not Working Replacing the Oven LightCustomer Care Department Service and Spare PartsElectrolux Guarantee conditions Guarantee ConditionsEuropean Guarantee ExclusionsImportant Safety Requirements Instructions for the InstallerBuilding OvenSecuring the oven to the cabinet This Oven Must be Earthed Electrical ConnectionGas connection Connecting the appliance to the gas supplyConversion from Natural to LPG Gas Replacement of gas oven burner injectorGas Oven Burner Data Replacement of Gas Type Label Replacement of gas grill burner injectorGas Grill Burner Data Minimum level adjustment of gas oven burner Customer Care