Electro-Voice X-Line Very Compact (XLVC) manual Complex Structural-Rating Analysis

Page 41

3.4 Complex Structural-Rating Analysis

For a complete structural-rating analysis, the forces in each individual piece of attachment hard- ware throughout the XLVC system must be determined, as well as the forces on each enclosure. Determining these forces requires complex mathematical calculations. All of these forces must then be compared to the working-load limits detailed below for each of the rigging points and the overall enclosures.

The reader should consult an experienced structural engineer to perform the complex structural analysis.

WHEN SUSPENDING ANY XLVC LOUDSPEAKER SYSTEM OVERHEAD, THE WORKING-LOAD LIMITS MUST NEVER BE EXCEEDED FOR EACH INDIVIDUAL RIGGING POINT, AND THE OVERALL ENCLOSURE.

3.5 XLD281, XLE181 and XS212 Complex Structural-Strength Ratings

There are two independent strength ratings that, together, give a complete description of the overall structural capabilities of the XLVC loudspeaker system - the working-load limits of the individual rigging points (the two hinge-bar assemblies and the two swing-arm assemblies) and the working-load limit for the overall enclosure assembly. The XLD281, XLE181 and XS212 each have unique working-load-limit ratings for the individual rigging points and the overall enclosure, and are shown in Figure 14a for the XLD281, Figure 14b for the XLE181 and Figure 14c for the XS212.

XLD281, XLE181 and XS212 Hinge-Bar Structural-Strength Ratings

The working-load limit of each of the hinge-bar rigging points on the XLVC enclosures is dependent on the hinge bar, the rigging tube, the quick-release pins, the enclosure and the angle of pull. Each enclosure has two hinge-bar rigging points - left and right. The structural ratings shown in Figure 14 are for a single rigging attachment point. That is to say, the left and right front hinge-bar rigging points each have the rating shown in the figure.

The front-to-back structural-strength ratings for the front rigging points cover a full 360° of rotation. Although it is not possible to put the front hinge bars into tension over 360°, it is possible for the hinge bars to go into compression with some array configurations. Therefore, the 360° rating is necessary to accommodate both tension and compression. It should also be noted from Figure 14 that the front hinge bars are only rated for side-to-side pull angles of a maximum of ±5°.

XLD281, XLE181 and XS212 Swing-Arm Structural-Strength Ratings

The working-load limit of each of the swing-arm rigging points on the XLVC enclosures is dependent on the swing arm, the rigging tube, the quick-release pins, the enclosure and the angle of pull. Each enclosure has two swing-arm rigging points - left and right. The structural ratings shown in Figure 14 are for a single rigging attachment point. That is to say, the left and right rear swing-arm, rigging points each have the rating shown in the figure.

ELECTRO-VOICE®X-Line Very CompactTM Rigging Manual

40

Image 41
Contents Line Very Compact Rigging Manual Table of Contents Rigging-Safety Warning XLD281 Loudspeaker System IntroductionXLE181 Loudspeaker System Xlvc Enclosure Rigging Hardware Details Line Very Compact Rigging SystemOverview of the Xlvc Flying System Typical Xlvc Flying System Without Coupler Beam Rigging Hardware XS212 Rigging HardwareWeight 48 lb 21.8 kg XLD281 Rigging Dimensions and WeightsXLE181 Rigging Dimensions and Weights Front View XS212 Rigging Dimensions and WeightsXlvc Rigging Accessory Details XLD Grid Rigging Dimensions and WeightsXLE Grid XLE Grid Rigging Dimensions and WeightsXLVC-BGK Cbeam Rigging Dimensions and WeightsAgcd Adapter Grid Dimensions and Weights XLVC-BGK Bottom Grid Kit ContentsSP8.4 XGS-4 Groundstack Details/DimensionsSP12.6 XLD/XS Dolly Rigging Xlvc Enclosures Together Xlvc Rigging and Flying TechniquesArray Considerations Front View Front ViewSide ViewFront ViewSide View Rigging XLD281 or XLE181 Systems Together Rigging XS212 Enclosures Together Rigging XS212 Systems TogetherRigging XS212 and XLD281 Enclosures Together Rigging XLD281 and XS212 Systems Together Rigging the Xlvc Loudspeaker Systems and Xlvc Grids XLD Grid and XLE Grid Rigging Assembly XLD Grid and XLE Grid Rigging Configurations Rigging the Xlvc Grids and the Cbeam Cbeam Rigging Assembly Cbeam Pick Up Options Cbeam Dual-Array Configuration Using Grid Positions a and CCbeam Single-Array Configuration Using Grid Position B Using the XLVC-BGK and Grid for Pull Up Cbeam Shipping/Transport ConfigurationAssembling the XLVC-BGK Using the Agcd with Xlvc and XLC Systems XLVC-BGK Rigging an Array from the Xlvc Dollies XLD/XS Dolly LiftColumn of Enclosures Working-Load Limit and Safety Factor Definitions Structural Rating Overview Simplified Structural-Rating Guidelines XLD281 Simplified Structural RatingsELECTRO-VOICEX-Line Very CompactTM Rigging Manual ELECTRO-VOICEX-Line Very CompactTM Rigging Manual XLD281, XLE181 and XS212 Complex Structural-Strength Ratings Complex Structural-Rating AnalysisXld281 Hinge Bar Working-Load-Limit Structural Ratings XLD281 Complex Structural RatingsXle181 Hinge Bar Working-Load-Limit Structural Ratings XLE181 Complex Structural RatingsXs212 Hinge Bar Working-Load-Limit Structural Ratings XS212 Complex Structural RatingsELECTRO-VOICEX-Line Very CompactTM Rigging Manual ELECTRO-VOICEX-Line Very CompactTM Rigging Manual Cbeam Complex Structural-Strength Ratings Agcd Complex Structural-Strength Ratings Cbeam Complex Structural RatingsWind Loading Electro-Voice Structural-Analysis ProceduresAgcd Adapter Grid Complex Structural Ratings Electro-Voice Xlvc Loudspeaker Systems Rigging Inspection and PrecautionsELECTRO-VOICEX-Line Very CompactTM Rigging Manual Mechanical Engineering References ReferencesRigging References Websites ELECTRO-VOICEX-Line Very CompactTM Rigging Manual ELECTRO-VOICEX-Line Very CompactTM Rigging Manual Telex Communications, Inc /2006 Part Number 38110-429 Rev a