Viking CDMOS200, CVMOS200 service manual Touch Control Panel Assembly

Page 26

CDMOS200

DMOS200

VMOS200

CVMOS200

TOUCH CONTROL PANEL ASSEMBLY

OUTLINE OF TOUCH CONTROL PANEL

The touch control section consists of the following units.

(1)Key Unit

(2)Control Unit (The Control Unit consists of Power Unit and LSI Unit).

The principal functions of these units and the signals commu- nicated among them are explained below.

Key Unit

The key unit is composed of a matrix, signals generated in the LSI are sent to the key unit through P00-P07.

When a key pad is touched, a signal is completed through the key unit and passed back to the LSI through P14, P15, P16, P17, AIN6 and AIN7 to perform the function that was requested.

Control Unit

Control unit consists of LSI, ACL circuit, indicator circuit, power source circuit, relay circuit, buzzer circuit, synchroniz- ing signal circuit, absolute humidity sensor circuit and back light circuit.

1)ACL

This circuit generates a signal which resets the LSI to the initial state when power is supplied.

2)Indicator Circuit

This circuit consists of 40 segments and 16 common electrodes using a Liquid Crystal Display.

3)Power Source Circuit

This circuit generates voltages necessary in the control unit from the AC line voltage.

In addition, the synchronizing signal is available in order to compose a basic standard time in the clock circuit.

Symbol

Voltage

Application

VC -5V LSI(IC1)

4)Relay Circuit

A circuit to drive the magnetron, fan motor, turntable motor and light the oven lamp.

5)Buzzer Circuit

The buzzer is responsive to signals from the LSI to emit audible sounds (key touch sound and completion sound).

6)Synchronizing Signal Circuit

The power source synchronizing signal is available in order to compose a basic standard time in the clock circuit.

It accompanies a very small error because it works on commercial frequency.

7)Door Sensing Switch

A switch to “tell” the LSI if the door is open or closed.

8)Back Light Circuit

A circuit to drive the back light (Light emitting diodes LD10- LD15).

9)Absolute Humidity Sensor Circuit

This circuit detects moisture of the cooking food to allow its automatic cooking.

24

Image 26
Contents Table of Contents Models CDMOS200 VMOS200Before Servicing CDMOS200 VMOS200 CVMOS200 When the testing is completed Before ServicingRequirements Microwave Measurement Procedure CanadaLeakage test with enclosure installed Leakage test without enclosureMicrowave Measurement Procedure USA Leakage testMicrowave Ovens DMOS200 CDMOS200 VMOS200 CVMOS200 Foreword If provided, Vent Hood, Fan assembly, Cooling Fan MotorViking Range Corporation Description SpecificationGeneral Information Grounding InstructionsVMOS200 model shown Oven DiagramMove the Round Grounding Prong from this Plug Description of Operating Sequence Power Level P-0 to P-90 CookingOperation OFF ConditionSensor Cooking Condition Cooking SequenceSchematic Door Closed Clock Appears on Display Imar Y IT C H C O Ndar Y S W IT C HDescription and Function of Components Troubleshooting Guide Problem Test ProceduresTest Procedure Procedure Letter Component Test Magnetron Assembly TestPower Transformer Test Procedure Letter Component TestMicrowave Output Power Magnetron Temperature Fuse Test Procedure Letter Component Test High Voltage Rectifier TestCavity Temperature Fuse Test High Voltage Capacitor TestSecondary Interlock System Test Door Sensing SwitchMonitor Switch Test Secondary Interlock Relay RY2Blown Monitor Fuse Test Touch Control Panel Assembly TestBefore testing Test Procedures KEY Unit TestCompu Defrost Test Weight 1ST Stage 2ND Stage Level TimeRelay Test Occurrence Cause or Correction Steps Occurrence Cause or Correction Checking the initial sensor cooking condition Testing Method for AH Sensor and /OR Control Unit AH Sensor Test Water load cooking testProcedure Letter Component Test Checking Control Unit Procedure Letter Component Test Noise Filter Test Measuring Point Indication of OHM-METERTouch Control Panel Assembly LSIIXA098DR Signal coming from touch key Signal synchronized with commercial power source frequencyKey strobe signal Signal similar to P17Pin No Power source voltage GND0VInternal clock oscillation frequency control input setting AH sensor inputSEG Segment data signalCommon data signal COM10 COM7 OUTAbsolute Humidity Sensor Circuit Structure of Absolute Humidity SensorServicing Tools Other PrecautionsTouch Control Panel Servicing Component Replacement and Adjustment Procedure Outer Case RemovalHigh Voltage Rectifier and High Voltage Capacitor Removal Power Transformer RemovalRe-install Magnetron RemovalOven Lamp and Lamp Socket Removal Positive Lock Connector NO-CASE Type RemovalControl Panel Assembly Removal Turntable Motor RemovalCooling FAN Motor Removal AH Sensor ReplacementRE-INSTALL RemovalDoor Replacement After adjustment, check the followingSealer Film After any service, make sure of the followingInstallation Diagram HIG H Voltag E C OmponeFigure S-2 Power Unit Circuit Circuit Figure S-3 CPUUnitFigure S-5 Printed Wiring Board of Power Unit Cabinet Parts Parts ListElectric Parts Control Panel PartsSCREWS,NUTS and Washers Door PartsMiscellaneous Oven and Cabinet Parts Control Panel Parts Door Parts Miscellaneous Packing and Accessories Copyright 2002 by Viking
Related manuals
Manual 45 pages 12.01 Kb