L I N E P R E S S U R E
T E S T I N G
Testing above 1/2 psi (3.5 kPa) 14" (35.6 cm) WC (gauge)
The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.5 kPa).
Testing below 1/2 psi (3.5 kPa) 14" (35.6 cm) WC (gauge) or lower
The range must be isolated from the gas supply piping system by closing its individual manual
E L E C T R I C A L
R E Q U I R E M E N T S
WARNING
Verify that power is discon- nected from junction box before proceeding.
•Maximum connected load:
5,200 W
10,000 W
•Required power supply: 240V / 30A / 60Hz
•Minimum supply wire size
12 AWG, neutral - 16 AWG, ground -
12 AWG.
•Minimum supply wire size
8 AWG, neutral - 12 AWG, ground -
10 AWG.
The terminal block on the rear of the range allows for
For UL installations: Attach the conductors to the residence wiring in accordance with National Electrical Codes and all state, municipal and local codes.
For CSA installations: Attach the conductors to the fuse box provided. Then connect the residence wiring to the fuse box in accordance with all national, provincial, and local codes. Then, depending upon local codes, utilize one of the following tech- niques to connect the appliance to the electrical power supply.
Connecting to a
•Cut and / or remove the ground strap on the terminal block.
•Connect the white appliance wire to the neutral (white) supply wire on the terminal block.
•Connect the black appliance wire to the black (L1) power supply wire on the terminal block.
•Connect the red appliance wire to the red (L2) power supply wire on the terminal block.
•Connect the ground appliance wire to the green /ground house ground- ing wire on the terminal block.