KitchenAid W10153187A, W10153153, W10153151 Venting Requirements, Electrical Requirements

Page 5

Venting Requirements

Vent system must terminate to the outdoors.

Do not terminate the vent system in an attic or other enclosed area.

Do not use 4" (10.2 cm) laundry-type wall caps.

Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61.0 cm) of straight vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the grill vent hood.

Use caulking to seal exterior wall or roof opening around the cap.

The size of the vent should be uniform.

Venting Methods

This canopy grill vent hood is factory set for venting through the roof or through the wall.

A 10" (25.4 cm) round vent system is needed for installation (not included). The hood exhaust opening is 10" (25.4 cm) round.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

Vent system can terminate either through the roof or through the wall. To vent through a wall, a 90° elbow is needed.

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

10" (25.4 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

90° elbow

5.0 ft

 

(1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

Example vent system

90 elbow

 

 

 

 

 

 

Wall cap

 

 

6 ft (1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2ft

(0.6 m)

The following example falls within the maximum recommended vent length of 35 ft (10.7 m).

1

- 90° elbow

= 5.0 ft (1.5 m)

1

- wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

 

 

Length of system

= 13.0 ft (3.9 m)

Rear discharge

A 90° elbow may be installed immediately above the hood.

Roof Venting

Wall Venting

 

C

 

 

B

B

C

 

A

A

 

D

 

D

A. Optional decorative duct cover

A. Optional decorative duct cover

B. 10" (25.4 cm) round vent

B. 10" (25.4 cm) round vent and

C. Roof cap

elbow

D. 10" (25.4 cm) round vent

C. Wall cap

transition

D. 10" (25.4 cm) round vent

 

transition

Electrical Requirements

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

5

Image 5
Contents WALL-MOUNT Canopy Grill Vent Hood Table of Contents Grill Vent Hood SafetyImportant Safety Instructions Location Requirements Installation RequirementsTools and Parts Electrical Requirements Venting RequirementsWood Mounting Strip Installation Installation InstructionsPrepare Location To Remove FiltersMake Electrical Connection Install Grill Vent HoodAttach Metal Transition Duct Piece Complete PreparationReinstall Grease Filters Install Duct CoverComplete Installation Check Grill Vent Hood OperationGrill Vent Hood Care CleaningGrill Vent Hood USE Replacing a Halogen Lamp To CleanTo Remove Metal Grease Filters To Replace Metal Grease Filters48 121.9 cm Model Wiring Diagrams30 76.2 cm and 36 91.4 cm Models Accessories Assistance or ServiceU.S.A CanadaThis limited warranty does not cover Whirlpool Corporation Major Appliance WarrantyPage Votre sécurité et celle des autres est très importante Sécurité DE LA Hotte DE CuisinièreConservez CES Instructions Outillage et pièces Exigences DinstallationExigences demplacement Exigences concernant lévacuation Dimensions de l’installationMéthodes dévacuation Décharge par larrièreCalcul de la longueur effective du circuit dévacuation Spécifications électriquesExemple de système de décharge Composant Conduit de diamètre 25,4 cm Coude àPréparation de lemplacement Instructions DinstallationInstallation de la bride de montage en bois de la hotte Dépose des filtresRaccordement électrique Installation de la hotte de cuisinièreFixation du conduit de connexion métallique Achever la préparationRéinstallation des filtres à graisse Installation du cache-conduitAchever linstallation Vérification du fonctionnement de la hotteNettoyage Utilisation DE LA HotteEntretien DE LA Hotte Remplacement des filtres à graisse métalliques Remplacement dune lampe à halogèneDépose des filtres à graisse métalliques NettoyageModèles 30 76,2 cm et 36 91,4 cm Modèle 48 121,9 cmAccessoires Assistance OU ServiceSi vous avez besoin de pièces de rechange Cache-conduits pour hotte dextérieurLa présente garantie limitée ne couvre pas Garantie DES Gros Appareils Ménagers Whirlpool CorporationW10153187A