4.Run 3 wires, black, white and green, in ¹⁄₂" conduit from service panel to terminal box. Use caulking to seal openings.
DE
F
C
B
G
A
H
A. Green (or bare) ground wire from home power supply connected to green ground screw
B. UL listed wire connectors (3) C. Black wires
D. Home power supply cable E. Green ground screw
F. Grill vent hood power supply cable G. Strain relief
H. White wires
5.Use UL listed wire connectors and connect black wires (B) together.
6.Use UL listed wire connectors and connect white wires (H) together.
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death, fire, or electrical shock.
7.Connect green (or bare) ground wire from home power supply to the unused green ground wire (A) in the terminal box.
8.Tighten strain relief screws.
9.Install terminal box cover.
10.Using the light bulb removal tool, check all light bulbs to make sure they are secure in their sockets.
11.Reconnect power.
Install Duct Cover
(Optional Accessory)
1.Use 4 - #10 sheet metal screws to assemble the duct cover sides to duct cover front.
2.From inside the grill vent hood, attach duct cover to the top of the grill vent hood using 8 - #10 sheet metal screws.
Reinstall Grease Filters
See “Metal Grease Filters” in “Grill Vent Hood Care” section.
Complete Installation
Check Grill Vent Hood Operation
1.Press the light button (B) to turn on the light, press again to turn light off.
2.Press fan button (A) “up” to turn fan on Low Speed. Press the fan button “down” to turn fan to High Speed.
3.Press fan button (A) to the middle position to turn off the fan.
4.If grill vent hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown.
8